7-8 Programming scan edges
Memory channels P1 and P2 are the program scan
edges. They are used to program an upper and lower
frequency for programmed scan (p. 56). By default, P1
is programmed with 0.50000 MHz and P2 is pro-
grammed with 29.99999 MHz. If P1 and P2 are pro-
grammed with the same frequencies, programmed
scan will not proceed.
[EXAMPLE]: Programming 14.00000 MHz into P1 and
14.350000 MHz into P2.
➀ Rotate [M-CH] to select scan edge P1.
➁ Rotate the tuning dial to set 14.00000 MHz as the
lower frequency.
➂ Push [MW] for 2 sec. to program 14.00000 MHz into
scan edge P1.
➃ Rotate [M-CH] to select scan edge P2.
➄ Rotate the tuning dial to set 14.35000 MHz as the
upper frequency.
➅ Push [MW] for 2 sec. to program 14.35000 MHz into
scan edge P2.
• When programmed scan is activated (p. 56) scanning will
search the frequencies between 14.00000 MHz and
14.35000 MHz for signals.
The call channel is programmed in the same way reg-
ular memory channels are. It’s convenient to program a
most-often-used frequency into the call channel for
quick recall. As with memory channels, the call chan-
nel can also hold split frequencies.
➀ Rotate [M-CH] to select the call channel.
•“C” appears.
➁ Select a frequency and operating mode to program
into the call channel.
➂ Push [MW] for 2 sec. to program the displayed fre-
quency and operating mode into the call channel.