9
CONTROL COMMAND
42
•Command table
Command Sub command Description
00 — Send frequency data
01 — Send mode data
02 — Read Upper/Lower frequencies
03 — Read frequencies
04 — Read operating mode
05 — Set operating frequency
06 — Set mode
08
— Set memory
— Set memory channel
0E
00 Scan stop
01 Memory scan start
11 — ATT
01 AF gain
14 02 RF gain
03 Squelch level
15
01 Read squelch Open/Close
02 Read S-meter level
02 PREAMP
16 22 Noise blanker
44 Microphone compressor
19 00 Read ID
■ Data cloning between transceivers
•Data cloning
The IC-78’s data (programmed frequencies, channel comment, both quick and initial set mode conditions, etc.) can
be copied to the other IC-78. This function is useful when exactly the same setting of the IC-78s is required.
•Cloning operation
q Turn power OFF.
w Connects a mini-plug cable between two IC-78’s
(master and sub) [REMOTE] jack.
e While pushing [TXF] and [FC], turn the master IC-
78 power ON.
r While pushing [SET] and [FC], turn the sub IC-78
power ON.
t Push [TONE] of the master IC-78 to start cloning.
• After cloning complete;
y Turn power OFF
indicates “M”.