7
45
SCANS
■ Scan types
Scanning searches for signals automatically and
makes it easier to locate new stations for contact or lis-
tening purposes. The IC-910H has several scan types;
programmed scan, memory scan and mode select
scan.
The scanning operation can be performed indepen-
dently for MAIN and SUB band. And to search a sub-
audible tone frequency for a repeater frequency, a tone
scan is also available.
■ Preparation
• Squelch condition
Set the [RF/SQL] control as for regular operation.
• When receiving a signal
•Scan pauses for 10 sec. when receiving a signal, then
resumes.
•When a signal disappears while scan is paused, scan
resumes approx. 3 sec. later.
• Scan resume ON/OFF
You can select the scan to resume or cancel when re-
ceiving a signal, in the scan set mode. Scan resume
ON/OFF must be set before operating a scan. See de-
tails described at right for ON/OFF setting.
• Scan start/stop operation
Push [SCAN .] to start and cancel scanning.
• Scan speed
Scan speed can be selected from 2 levels, high (de-
fault) or low, in the scan set mode. See details de-
scribed at right.
• Setting scan resume condition
q Push [SET] then [SCAN .] to enter the scan set
mode.
w Push [DN ▼] or [▲ UP] to select the scan resume
item.
•“SC-rES” is displayed.
e Rotate the tuning dial to select scan resume condi-
tion from ON and OFF.
•“ON”: scan resumes, “oFF”: scan cancels
• Push [M-CL-5] for 1 sec. to return to the default setting.
r Push [SCAN .] to exit from the scan set mode.
• Setting scan speed
q Push [SET] then [SCAN .] to enter the scan set
mode.
w Push [DN ▼] or [▲ UP] to select the scan speed
item.
•“SC-SPd” is displayed.
e Rotate the tuning dial to select scan resume condi-
tion from HI and Lo.
• Push [M-CL-5] for 1 sec. to return to the default setting.
r Push [SCAN .] to exit from the scan set mode.
(scan edge memory channels 1A/2A/3A and 1b/2b/3b).
This scan operates in VFO mode.
scan edge frequency.
Repeatedly scans all selected mode memory channels.
This scan operates in memory mode.