27
7
SCANS
■ Priority watch operation
Priority watch checks for signals on a frequency every
5 sec. while operating on a VFO frequency.
q Select memory mode with [V/M].
w Select the desired memory channel to be watched
with [UP Y] or [Z DN].
e Select VFO mode.
r Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control, the
squelch always opens. See pgs. 14, 30 for details.
t Push [SCAN] for 2 sec. to start priority watch.
•“SCAN” appears.
y When a signal is received on a watch channel, the
function display shows the watch channel and
“SCAN” blinks.
u To cancel the watch, push [SCAN].
■ Auto memory write scan
Auto memory write scan operates in the same way as
programmed scan. However, when a signal is re-
ceived, the received frequency is automatically writ-
ten into memory channels (80 to 99).
When the auto memory write scan starts, the pre-
viously written memory channels (80 to 99) are
cleared.
q Select VFO mode with [V/M].
w Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
e Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control, the
squelch always opens. See pgs. 14, 30 for details.
r Push [SCAN] to start the programmed scan.
•“SCAN” appears while scanning.
• If the same frequencies are programmed into the scan
edge memory channel P1 and P2, programmed scan
does not start.
t Push [MW] to start the auto memory write scan.
•“80” blinks when auto memory write scan starts.
y When the scan detects a signal, the frequency is
programmed into a memory channel (80 to 99),
starting from channel 80.
u To cancel the scan, push [SCAN].