36
7
SCAN OPERATION
■ Scan edges programming
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 00A/00B to 24A/24B, in memory channels.
qPush [VFO MHz] to select VFO mode.
wSet the desired frequency:
➥ Select the desired band with [BAND].
➥ Set the desired frequency with [R-DIAL].
➥ Set other data
(e.g. offset frequency, duplex direction, tone
squelch, etc.), if desired.
ePush [MR S.MW] for 1 sec. to select select memory write
condition.
•1 short and 1 long beeps sound.
•“
µµ
” indicator blinks.
rRotate [R-DIAL] to select the desired programmed scan
edge channel from 00A to 24A.
tPush [MR S.MW] for 1 sec.
•3 beeps sound
• The other scan edge channel “B,” 00B to 24B, automatically se-
lected when continuing to push [MR S.MW] after programming.
yTo program a frequency for the other pair of scan edges,
00B to 24B, repeat steps w and r.
• If the same frequency is programmed into a pair of scan edges,
programmed scan will not function.