These technical instructions have been prepared for use by Authorised persons. This unit must only be
installed by an Authorised person. The installation must be carried out by qualified personnel in
accordance with the relevant requirements of the Gas Safety Regulations, the local Building Regulations.
Gas connection
Gas-powered devices for home use, which are not connected to a conduit for the evacuation of
combustion products, must not cause a concentration of carbon monoxide that could pose a health risk
to the persons exposed in relation to the time of exposure. We recommend checking that the appliance is
properly set up for the type of gas distributed. The connection to the gas pipes must be made in a
workman like manner, in compliance with current standards that prescribe the installation of a safety tap at
the end of the pipe. The Gas Connection is male ½” BSP and is situated at the right hand rear of the
appliance.
During installation ensure that the flexible connection be located so as to prevent excessive operating
temperatures affecting the hose. Under no circumstance is the temperature of the flexible connection to
exceed its approved rating. The flexible connection should also be checked visually for any abrasion,
defect or kinking and replaced or repositioned to prevent abrasion, kinking and permanent deformation if
necessary. Always ensure that a restraining chain, if fitted, be correctly fitted so that strain is not placed on
the household plumbing.
It is recommended that an isolating valve and union be fitted, to enable simple disconnection for servicing.
These are to be in an accessible location.
Natural Gas
The appliance is factory set for Natural gas and is supplied with a 1kPa regulator that must be fitted to the
gas supply to the appliance.
ULPG Gas
The ULPG gas pressure regulator must be set to provide a supply pressure of 2.75kPa conforming to
standards regulations in force should be fitted. Fit the test point assembly supplied with the appliance to
the gas connection when installing for use with ULPG Gas.
It is possible to connect the gas in the following ways:
This appliance is suitable for use with either a flexible connection or rigid copper connection. If installing
the appliance with a flexible connection the flexible connection must be Australia Gas Association
approved to class B of AS/NZS1869 as a minimum. Using a Plumbezy flexible hose, AGA approval
number 6196, 10mm ID, class D and between 1-1.2m long in accordance with AG601 for a “high level
connection”.
installation - gas supply
Built-in cooktops
20 ILVE Built-in Cooktop Operating & Installation Manual
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ilve H30 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info