57
GB
TECHNICAL DATA
Power supply 220-240 V~, 50Hz
Maximum absorbed power 3200 W
Microwave power 900 W
Grill 1500 W
Hot air 1500 W
Microwave frequency 2450 MHz
ELECTRICAL HOOK-UP
Before making the electrical hook-up, make sure that:
- the characteristics of the electrical system satisfy what is shown on the serial number plate applied to the front
of the oven;
- the electrical system has an effect earth connection conforming to standards and current law.
The earth connection is required by law.
The cable must not, at any point, reach a temperature greater than 50 °C above the ambient temperature.
This oven must be connected to the supply by a supply cord fitted with an appropriately rated plug that is
compatible with the socket-outlet fitted to the final sub-circuit in the fixed wiring that is intended to supply this
oven.
If a fixed appliance does not have a power cord and plug, or another device that ensures disconnection from
the mains, with an opening distance of the contacts that allows complete disconnection under the conditions
of excessive voltage category III, such disconnection devices must be provided in the power supply mains
conforming to the installation rules.
The omnipolar socket or switch must be easy to reach when the appliance is installed.
NOTE: The manufacturer declines all liability if the usual accident prevention standards and the above instructions
are not followed.
TYPE AND MINIMUM DIAMETER OF THE CABLES
SASO
H05RR-F 3x1,5 mm² H05RR-F 3x2,5 mm²
H05VV-F 3x1,5 mm² H05VV-F 3x2,5 mm²
H05RN-F 3x1,5 mm² H05RN-F 3x2,5 mm²
H05V2V2-F 3x1,5 mm² H05V2V2-F 3x2,5 mm²