475148
2
Zoom out
Zoom in
Vorherige Seite
1/80
Nächste Seite
2
EN
Installation
1
0
m
m
15 mm
15 mm
15 mm
15 mm
B
A
Where to install the tumble dryer
 Install the dryer far from gas
ranges, stoves, radiators or hobs,
as flames may damage it.
If the dryer is installed below a
worktop, ensure there are 10 mm
between the upper panel of the
dryer and any objects above it,
and 15 mm between the sides of
the machine and the walls or
furniture units adjacent to it. This
ensures adequate air circulation. Make sure the air inlets on
the rear panel are not blocked or obstructed.
You should also make sure that the room in which the
tumble dryer is installed is not damp, and that it is
adequately ventilated.
We do not recommend that the dryer is installed in a
cupboard but the dryer must never be installed behind a
lockable door, a sliding door or a door with a hinge on the
opposite side to that of the dryer door.
Ventilation
This appliance gently dries laundry by taking in cold, clean and
relatively dry air, heating it and passing it through the fabric.
To facilitate the drying process, damp air is expelled at the
rear, through a ventilation hose. When the dryer is in use, there
has to be adequate ventilation to avoid a back flow of gases
into the room from appliances burning other fuels, including
open fires.
Mobile ventilation system
When using the tumble dryer with the mobile ventilation
system, a ventilation hose must be connected. The hose
should be securely fastened to the ventilation hole at the rear of
the appliance (see Description of the tumble dryer). We
recommend the hose is connected to an outlet near the tumble
dryer, if possible. If it cannot be installed in a permanent spot,
the tumble dryer will still function perfectly well if the ventilation
hose is passed through a partially-opened window.
Make sure you do not point the ventilation hose towards the
air inlet, which is located on the rear of the appliance.
The ventilation hose should not exceed a maximum length of
2.4 metres; it should also be shaken frequently to remove any
fluff, dust or water deposits inside it. Make sure you do not
crush the hose.
Fixed ventilation system
We recommend the ventilation hose is connected to a
ventilation system for windows or doors, available from the
retailer which originally sold you the appliance or from your
local spare parts stockist.
Wall ventilation hole
1. Leave an opening in the wall
to the left of the tumble dryer
installation site.
2. Make the hose as short and
straight as possible, in order to
prevent any moisture from
condensing and leaking back
into the appliance.
3. The hole in the wall must
also be straight and pointing
downwards, so that the flow of air coming out is not
impeded.
Areas A and B should be checked frequently, to prevent the
accumulation of fluff or debris, particularly if the tumble dryer
is used very often. The hose adaptor must be fitted
correctly, in order to prevent damp air from coming back
into the room.
Window ventilation hole
The ventilation hole should be
directly behind the dryer in
order to keep the hose as short
as possible.
Make sure you do not push
the tumble dryer too far
backwards, as this could lead
to the ventilation hose being
crushed, bent or even
disconnected.
There should be no cuts, kinks or U-shaped bends in the
hose, as these could impede ventilation or trap
condensation.
Ventilation through an open window
The end of the hose must be
facing downwards, in order to
prevent the hot, damp air from
forming condensation in the
room or the tumble dryer.
Make sure that the tumble dryer is adequately ventilated,
and that the end of the ventilation hose is not pointing
towards the air inlet pipe on the rear of the appliance.
The ventilation hose must always be fitted to ensure
optimum performance.
Make sure that the ventilation hose and the air inlet vents
are not obstructed or blocked.
Do not let the tumble dryer recirculate exhaust air.
Improper use of the tumble dryer may result in fire hazards.
The air emitted by the tumble dryer must not be expelled in
the same duct as used for the fumes produced by different
appliances which burn gas or other fuels.
Do not discharge the exhaust air into an extraction system
or any duct with an extractor fan. This will affect the way the
thermal controls operate and can result in a fire hazard.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Indesit IDVA 835 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info