SETUP INSTRUCTIONS
Be sure you have access to water to fill the pool and chemicals for the water.
IMPORTANT: This filter pump is shipped with the air release valve (1) open (open the air
release valve if necessary). DO NOT replace the air release valve until you reach STEP #8.
Failure to follow these instructions will result in air trapped inside filter housing; the motor
will run dry, be noisy and malfunction.
1.
Assemble above-ground-pool first. Carefully follow the pool’s installation instructions.
2.
Place the filter pump the length of the hose away from the pool wall where the lower black
protruding hose connection is "sticking-out". Ensure the filter pump is accessible at all time for
service and maintenance.
3.
Insert the nozzle union
(14 & 10)
into the upper protruding hose connections, and then attach
the pool inlet air adaptor
(16)
to the upper protruding fitting. Screw the air jet valve
(15)
over
the pool inlet air adaptor
(16)
. Then insert the strainer union
(9 & 11)
into the lower protruding
hose connections. The hoses
(8)
fit over the strainers inserted into the connections.
4.
There are two hoses to be connected to the filter pump hose connections. With hose clamps
(7)
,
fasten one of the hoses
(8)
to the lower protruding hose connection (marked "+" on the pool
liner) and to the upper pump connection (marked "+").
5.
Connect the second hose to the pool inlet air adaptor
(16)
and to the lower pump connection.
Make sure all the hose clamps
(7)
are tight.
NOTE:
Make sure the air jet valve
(15)
is securely
tighten onto the pool inlet air adaptor
(16)
and facing up.
6.
In a counter-clockwise motion unscrew the threaded filter housing collar
(13)
from the filter
housing. Grasp and remove the housing cover
(3)
. Check to see if a cartridge is inside the
housing. If yes, replace the cover, finger tighten the housing collar
(13)
back onto the filter
housing.
7.
Fill the pool to a level of at least 1-2 inches above the top connection. The water will
automatically flow down into the pump.
8.
When water starts flowing out of the air release valve hole, screw in the air release valve back
into the filter housing cover. Do not over tighten the valve.
NOTE: Venting the system is
necessary for air to escape as the filter housing fills with water.
9.
Connect the filter pump power cord end to the transformer output receptacle and screw in the
cover. Plug the transformer power cord into a properly installed electrical socket.
10.
Operate the filter pump until the desired water clarity is obtained.
NOTE:
Never put pool chemicals directly into the filter pump. This may damage the pump
and void the warranty.
WARNING
Risk of electric shock. Connect transformer only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or residual
current device (RCD). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI/RCD. Use a qualified electrician
to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a
portable residual current device (PRCD).
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Intex 604G Krystal Clear filterpomp wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Intex 604G Krystal Clear filterpomp

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Deutsch - 14 seiten

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Holländisch - 15 seiten

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Französisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info