1.
Before emptying your pool for long term storage, or relocation, be sure the water is directed
towards an acceptable drain water receptacle away from the house. Check local regulations
for specific directions regarding disposal of swimming pool water.
2.
Now, drain the pool.
3.
When the pool is empty, disconnect all pool hoses
(8)
from the pool and filter pump, simply
reverse the set up instructions.
4.
Remove the filter cartridge as shown in the Filter Cartridge Cleaning section, steps 2 thru 4.
5.
Remove the nozzle and strainer unoins from the pool wall. Place the wall plugs into the
hose connections. Loosen clamps
(7)
securing the strainer connectors
(9)
before removal.
6.
Drain water from the filter pump housing.
7.
Leave filter pump pieces and hoses outside to thoroughly air dry.
8.
Depending on the cartridge
(5)
usage, a new cartridge may be needed for next season,
keep a spare available.
9.
Cover the seal
(4)
, air release valve O-ring
(2)
and hose seals
(6)
with petroleum jelly to
preserve its resilience during storage.
10.
Store the unit and accessories in a dry place. The storage's temperature should be
controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit
(40 degrees Celsius) storage location.
11.
The original packing can be used for storage.
LONG TERM STORAGE
It is recommended that the filter cartridge be replaced at least every 2
weeks. Regularly monitor the filter clogging level.
1.
Make sure the transformer power cord is not plugged into the electrical socket.
2.
To prevent water from escaping the pool, unscrew the pool inlet nozzle
(10)
and strainer
grid
(11)
from the strainer connectors and insert the hat-like plugs into the strainer
connectors.
3.
In a counter-clockwise motion, remove the filter housing collar
(13)
and threaded cover
(3)
.
Be careful not to lose the cover seal
(4)
.
4.
Remove filter cartridge
(5)
to clean it. The filter may be cleaned from the spray from a water
hose.
5.
Use judgement as to whether cartridge needs to be replaced. Only use the original Intex
cartridge for replacement. See “Parts Reference” section for detail.
6.
Return cartridge to filtering position.
7.
Return the seal
(4)
and threaded cover
(3)
to their original positions and in a clockwise
direction rescrew the housing collar
(13)
onto the filter housing.
8.
After service, open the air release valve, remove the plugs, allow any air to escape through
the valve before tightening the valve again and replace the pool inlet nozzle
(10)
and
strainer grid
(11)
. The pump is now primed with water again and may be turned on.
9.
Check the inlet and outlet openings regularly to ensure they are not obstructed thus
preventing a good filtration.
10.
The disposal of any used filter media should be in accordance with applicable local
regulation and legislation.
CLEANING OR REPLACING FILTER CARTRIDGES
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Intex 604G Krystal Clear filterpomp wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Intex 604G Krystal Clear filterpomp

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Deutsch - 14 seiten

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Holländisch - 15 seiten

Intex 604G Krystal Clear filterpomp Bedienungsanleitung - Französisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info