686579
20
Zoom out
Zoom in
Vorherige Seite
1/21
Nächste Seite
254
A
S AVE THESE INSTRUCTIONS
(254IO) SPA ENGLISH 7.5” X 10.3” PANTONE 295U 01/28/2016
English
TROUBLESHOOTING
Page 20
NO DISPLAY/SPA
CONTROL UNIT DOES
NOT WORK
HOUSEHOLD CIRCUIT
BREAKER TRIPPED
NOT HEATING
PROPERLY
BUBBLE AIR BLOWER
DOES NOT WORK
FILTRATION PUMP
NOT WORKING
WATER NOT CLEAN
PUMP CONNECTORS
ARE NOT LEVEL WITH
THE SPA CONNECTORS
TUB HAS A STRANGE
SHAPE
TUB LOSES AIR
PRESSURE
LEAKING BETWEEN SPA
TUB CONNECTORS AND
CONTROL UNIT
CONNECTORS
SPA IS TOO NOISY IN
FILTRATION MODE ONLY
Spa is unplugged or off.
Control panel cable plug loose.
• Power failure.
• RCD tripped.
• RCD broken.
Circuit breaker under rated.
Overloaded circuit breaker.
An electrical fault in the line.
Temperature set too low.
• Dirty lter cartridge.
Water temperature decreasing during
heater STANDBY mode.
Heating element failed.
Air blower pump is too hot.
• Dirty lter cartridge.
Filtration inlet and/or outlet clogged.
Filter pump motor failed.
Cartridge assembly not properly attached.
• Insuf cient ltering time.
• Dirty lter cartridge.
Improper water maintenance.
Filtration inlet and outlet clogged.
One characteristic of PVC is that
it changes shape, which is normal.
Expanded internal air pressure by
strong sunshine.
Air valve cap loose.
Air valve base loose.
Hole, cut or split on spa tub.
Spa control base inlet/outlet connections
not securely tight.
Spa control base inlet/outlet o-ring
missing/dirty.
Control base components not securely
attached.
Control base ground not level and rm.
• Spa lter motor failed.
Ensure the spa is plugged and switched on.
Ensure the control panel cable plug is rmly
attached to the control base receptacle.
Check power source.
Reset the RCD.
Contact Intex Service Center.
Ensure correct circuit breaker rating.
Provide a dedicated circuit breaker feeding the
spa electrical outlet only.
Contact a qualify electrician to correct the
electrical fault.
Increase the temperature and attach the spa
cover.
Clean or replace the lter cartridge in time.
If heater is in STANDBY mode, press the ame button
twice to heat up the water to the set temperature.
Contact Intex Service Center.
Turn off and unplug the spa. Let it cool down and
restart all over again.
If problem persists contact Intex Service Center.
Clean or replace the lter cartridge in time.
Check and clean ltration inlet and outlet regularly.
Contact Intex Service Center.
Ensure the cartridge assembly is properly attached.
Increase ltration time.
Clean or replace the lter cartridge in time.
Keep the spa water properly sanitized. Refer to the
chemical manufacturer’s instructions.
Check and clean ltration inlet and outlet regularly.
Elevate the pump with wood or another type of
insulated material to bring the pump’s connectors
level with the spa’s connectors.
Do not expose the product under direct sunshine.
Check the air pressure and release air if necessary.
During very hot weather, you must check to see
whether it is necessary to release some air. This is
to avoid any possible damage to the tub.
Ensure air valve cap is securely closed.
Fill up the spa tub with air then make sure the
air valve base is tighten, see “Spa Tub Air Valve
Fastening” section.
Put liquid soap and water in a squirt bottle and spray on
seams. If there is a leak it will bubble. After you nd the leak,
clean and dry the leaking area, then apply the repair patch
that comes with your spa.
Tighten inlet and outlet connections.
Coat the o-ring with petroleum jelly for water proof.
Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and not
damaged.
Ensure control panel, back cover and all inlet/outlet
are securely connected.
Ensure ground is level, rm and smooth.
Replace the failed lter motor with a new one.
PROBLEM CAUSE SOLUTION
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

intex-purespa-28404---ssp-h-20-1g

Suche zurücksetzen

  • hallo,mein Intex Pure spa SSP H. Wie kann ich in mein Pool im Trockenustand Luft hinzufügen. Hat über Winter an Luft verloren Eingereicht am 23-3-2022 10:15

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Intex PureSpa 28404 - SSP-H-20-1G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Intex PureSpa 28404 - SSP-H-20-1G

Intex PureSpa 28404 - SSP-H-20-1G Bedienungsanleitung - Deutsch - 24 seiten

Intex PureSpa 28404 - SSP-H-20-1G Bedienungsanleitung - Holländisch - 25 seiten

Intex PureSpa 28404 - SSP-H-20-1G Bedienungsanleitung - Französisch - 21 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info