752336
13
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
128
GS
SAVE THESE INSTRUCTIONS Page 13
(128GS) MODEL SF20220R SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 10/28/2011
English
OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS
OPERATING INSTRUCTIONS
Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or
residual current device (RCD). Contact a qualified electrician if you cannot
verify that the receptacle is protected by a GFCI/RCD. Use a qualified
electrician to install the GFCI/RCD, which has a maximum rate of 30mA.
Do not use a portable residual current device (PRCD).
To reduce the risk of electric shock, do not use extension cords, timers,
plug adaptors or converter plugs to connect unit to electric supply;
provide a properly located outlet.
Do not attempt to plug in or unplug this product while standing in water
or when your hands are wet.
Never operate this product above the maximum working pressure stated
on the filter tank.
Always switch off pump before changing the 6-way valve position.
Operating this product without water flowing through the system can
cause a build up of hazardous pressure which can result in an explosive
situation, serious injury, property damage or death.
Never test this pump with compressed air. Never operate the system with
water temperature above 35° C (95° F).
Valve Position Function Water Flow Direction
FILTER
(see drawing 14)
Normal filtration and regular
vacuuming of pond
From pump through filter media
to pond
BACKWASH
(see drawing 15)
Reverses water flow to clean
filter media
From pump through filter media
to valve waste/drain outlet
RINSE
(see drawing 16)
For initial startup cleaning of the sand, and
leveling the sand bed after backwashing
From pump through filter media
to valve waste/drain outlet
WASTE
(see drawing 17)
For vacuuming directly to waste,
lowering pond level or to drain the pond
From pump to valve waste/drain
outlet bypassing the filter media
RECIRCULATE
(see drawing 18)
For circulating water back to pond
without going through the filter media
From pump through valve to
pond bypassing the filter media
CLOSED
(see drawing 19)
Shuts off all flow to filter and pond
“Do not use this setting with pump running”
6-way valve positions and function:
WARNING
RE
T
L
I
F
E
S
N
I
R
ET
A
L
U
C
RI
C
E
R
E
S
O
LC
ETSA
W
E
S
N
I
R
ETALU
C
RICER
H
S
A
W
K
C
A
B
E
S
O
L
C
E
TSAW
R
E
T
L
I
F
E
S
N
I
R
E
TALU
C
RICER
H
S
A
W
K
C
A
B
ETSA
W
R
E
T
LI
F
E
S
NI
R
ER
H
S
A
W
K
C
A
B
E
SO
L
C
ETSAW
R
E
T
L
I
F
ES
N
I
R
E
TA
L
U
C
R
I
CE
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E
TL
I
F
ETALUC
R
ICER
H
S
A
W
K
C
A
B
E
S
O
L
C
ETSAW
B
14
RE
T
L
I
F
E
S
N
I
R
ET
A
L
U
C
RI
C
E
R
E
S
O
LC
ETSA
W
E
S
N
I
R
ETALU
C
RICER
H
S
A
W
K
C
A
B
E
S
O
L
C
E
TSAW
R
E
T
L
I
F
E
S
N
I
R
E
TALU
C
RICER
H
S
A
W
K
C
A
B
ETSA
W
R
E
T
LI
F
E
S
NI
R
ER
H
S
A
W
K
C
A
B
E
SO
L
C
ETSAW
R
E
T
L
I
F
ES
N
I
R
E
TA
L
U
C
R
I
CE
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E
TL
I
F
ETALUC
R
ICER
H
S
A
W
K
C
A
B
E
S
O
L
C
ETSAW
B
15
RE
T
L
I
F
E
S
N
I
R
ET
A
L
U
C
RI
C
E
R
E
S
O
LC
ETSA
W
E
S
N
I
R
ETALU
C
RICER
HSA
W
K
C
A
B
E
S
O
LC
E
TSAW
R
E
T
L
I
F
E
S
N
I
R
E
TALU
C
RICER
H
S
A
W
K
C
A
B
ETSA
W
R
E
T
LI
F
E
S
NI
R
ER
H
S
A
W
K
C
A
B
E
SO
L
C
ETSAW
R
E
T
LIF
ES
N
I
R
E
TA
L
U
C
R
I
CE
R
H
S
A
W
K
C
A
B
E
S
O
L
C
R
E
TL
I
F
ETALUC
R
ICER
H
S
A
W
K
C
A
B
E
S
O
L
C
ETSAW
B
16
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Intex SF20220 Pump wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Intex SF20220 Pump

Intex SF20220 Pump Bedienungsanleitung - Deutsch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info