INSTALLATION MANUAL
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
MODELS:
V4MFI-66B / V4MFO-66B
AIR CONDITIONING SYSTEMS
FLOOR STANDING
1
CONTENTS
SAFETY PRECAUTIONS
Warning .............................................................................................................................................2
Caution ..............................................................................................................................................2
INSTALLATION INSTRUCTIONS
Accessories .......................................................................................................................................3
Selecting installation place ................................................................................................................4
PIPE CONNECTION
Refrigerant pipe connection ..............................................................................................................7
Drain pipe connection ......................................................................................................................10
Inside you will find many helpful hints on how to install and test the air conditioner properly.
All the illustrations and specifications in the manual are subject to change without prior notice for product
improvement. The actual shape should prevail.
Contact an authorised service technician for repair or maintenance of this unit.
Contact an authorised installer for installation of this unit.
The air conditioner is not intended for use by young children or infirmed persons without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.
Installation work must be performed in accordance with the National Wiring Standards by authorised
personnel only.
CAUTION
Read This Manual
ELECTRICAL WORK
Wire connection ...............................................................................................................................11
TEST RUNNING
Test running ...................... .............................................................................................................13
2
SAFETY PRECAUTIONS
WARNING
Read the follow SAFETY PRECAUTIONS carefully before installation.
Electrical work must be installed by a licensed electrician. Be sure to use the correct rating
and main circuit for the model to be installed.
Incorrect installation due to ignoring of the instruction will cause harm or damage.
The seri ousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
The items to be followed are classified by the symbols:
Symbol will background white denotes item that is PROHIBITED from doing.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
1) Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water
leakage, electrical shock, or fire.
2) Install according to this installation instructions strictly. If installation is defective, it will cause water leakage,
electrical shock, or fire.
3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall,
water leakage, electrical shock, or fire.
,
4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough or
installation is not properly done, the set will drop and cause injury.
5) For electrical work, follow the local national wiring standard, regulation and this installation instructions. An
independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in
electrical work, it will cause fire or electrical shock.
6) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on
the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover
is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.
8) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.
9) Do not modify the length of the power supply cord or use of extension cord, and do not share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
CAUTION
1) This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical
shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.
4) The appliance shall be installed in accordance with national wiring regulations.
5) Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
6) An all-pole disconnection device which has at least 3mm clearances in all poles , and have a
leakage current that may exceed 10mA, the residual current device (RCD) having a rated residual
operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
3
INSTALLATION INSTRUCTIONS
4
5
6
10
9
18
19
1
2
Refrigerant Pipe (optional)
Name capacity(Btu/h)
21000-36000 36000-55000
NO.
Liquid Side Size
Gas Side Size
Diam.: 9.52mm
Diam.: 15.9mm
Diam.: 12.7mm
Diam.: 19mm
Diam.: 6.35mm
Diam.: 12.7mm
Bushing-Sleeve Cover
Sound/Heat Insulation Sleeves
Seal
Drain joint
7
8
1
1
NO.
1
2
3
1
2
2
Part Name
Safety Lock
Self-tapping Screw 3.9 25
Flat Washers
Quantity Illustrations
11
12
13
14
17
Remote Battery
Remote Controller
Connection Cables
Remote controller manual
User's manual
Installation manual
Cord protection rubber ring
(
)
If the cord clamp can not fasten the cord for the
small size of the cord, please use the cord
protection rubber ring(supplied with accessories) to
wrap on the cord, then fix it with the cord clamp.
2
1
1
1
1
1
1
on some
models
Before installing, please check the available accessories according to the list given below.
Please carefully keep the temporarily useless parts.
If there is any difference between the above table and the Packing List, the Packing List shall prevail.
.
¡£
(C)
ADJUST
AUTO
COOL
DRY
HEAT
HEALTH
HIGH
LOW
MODE
FAN SPEED
SWING
TIMER ON
SLEEP
ON/OFF
TIMER OFF
AIR
DIRECTION
RESET LOCK
SET TEMPERATURE
CLEAN
AIR LED
DISPLAY
Accessories
Pipe - hole - protection Ring
1
18000
15
16
Remote controller holder
Self-tapping Screw B ST2.9 10
1
Optional
parts 2
4
1-1 Indoor Unit
1-2 Outdoor Unit
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
Do not install the unit near the door way.
There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet and affect
its appearance. If unavoidable, sunlight prevention should be taken into consideration.
( wall or obstacle )
4cm
(min)
>30(cm)
(min)
50cm(min) 50cm(min)
Front
>200cm
Rear
5cm
(min)
(1) Please stand the unit in hard and flat ground;
Please reserve space for installation and maintenance.
(1) Before installing the outdoor unit, you should:
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
Select a place that is easy to connect indoor unit's pipe and electric wires.
Avoid a place where combustible gas may leak or stay.
Pay attention that water may drain out of the outdoor unit while in "Heat" mode.
Ensure the enough space around the back and sides and the front of the unit.
Take the air conditioner weight into account and select a place where noise and vibration are
minimum.
(2) Please check the elevation difference between the indoor unit and the outdoor unit, the length of the
refrigerant pipe, and the curved places (bend) of the pipe are no more than the following numbers:
Elevation difference: no more than 10 M (if the elevation difference between indoor and outdoor unit
is more than 10 meters, it is recommended that the outdoor unit be located
higher than the indoor unit.)
Pipe length: no more than 20 M
Bends: no more than 3 places
( Ceiling)
The outdoor unit should be put in a position that guarantees the minimum space for sufficient air
circulation and to allow maintenance work and the connections of electrical and refrigerant circuit lines.
It may be installed on a floor or flat roof or wall-mounted, provided its weight is properly supported and
there is no transmission of vibration to the adjacent rooms.
Selecting installation place
INSTALLATION INSTRUCTIONS
5
(2) If the outdoor unit is to be installed on a roof or where no constructions are around, you should avoid
hard wind blows directly to the air outlet, because it may cause trouble for air-flow shortage.
(3) Reserve enough space for installation, maintenance and unit-functioning.
Remove as many obstacles as possible nearby.
When the air-in surface is facing a wall
When the air-out surface is facing a wall
Maintenance
Side
Air Out
Air Out
Air In
Air In
Air In
Air In
(Wall or Obstacle)
(Wall or Obstacle)
>300cm
>30cm
>30cm
>50cm
>50cm
Maintenance
Side
Maintenance
Side
For example:
Let the air outlet face a wall (if there is one)
with a distance about 300 centimeters bet-
ween them.
Try to make the air outlet vertical to wind
direction if it is known in the season you use
the system.
Keep the spaces indicated by arrows from
wall, fence or other obstacles.
Strong Wind
Strong Wind
Air Out
A B
C
Caution
(1) A place full of machine oil.
(2) A saline place such as coast.
(3) Hot-spring resort.
(4) A place full of sulfide gas.
(5) A place where there are high frequency machines such as wireless installation, welding
machine, medical facility.
(6) A place of special environmental conditions.
Installation in the following places may cause trouble. If it is unavoidable to use in such places, please
consult with the dealer.
INSTALLATION INSTRUCTIONS
6
INSTALLATION INSTRUCTIONS
Drain Pipe
Reamer Joint
Pipe/wire-hole positions on both sides
Wiring
Holeφ35
Refrigerant/drain
Pipe holeφ85
Reamer Joint
Refrigerant Pipe
(2) Remove the Pipe Clip before connecting the pipes and wiring; fix it again after finishing connection.
Use accessories 4 and 8 to connect the pipes/wires on both sides and back side.
1 Indoor Unit
Lower front
panel
(1) Dismounting the lower front panel
Please take off the lower front panel before connecting
the pipes/wires.
Pull down the two knobs on the grille, take off the
two screws, then the air-inlet grille goes free.
Pipe/wire-hole position on back side
Pipe/wire-hole position on the bottom
Wiring
Holeφ35
Refrigerant/drain
Pipe holeφ85
Refrigerant/drain
Pipe holeφ85
7
PIPE CONNECTION
Ship the to the installation place originally packed;
Be careful while hanging the unit because the center of gravity of the unit is not centralized;
Do not make the angle of inclination more than 45 degrees while shipping;(Avoid horizontal
storage)
Be sure the electric insulation work is well done if installed on metal ceiling / wall.
air conditioner
Fix the unit feet with bolts (M10/M8). Be sure the unit is fixed strongly enough to against blast
or earthquake.
Make a concrete basement to the unit by the above references.
2 Outdoor Unit
The refrigerant pipe and the drain pipe should be heat-insulated to avoid condensing and
water-dropping.
A reamer joint is adopted to connect the indoor unit with the outdoor unit.
The refrigerant pipe is used to connect indoor and outdoor units, showed as below.
The pipe can not be curved for more than 3 times.
Cover all exposed reamer joint pipes and refrigerant
pipes with heat-insulation material.
NOTE
Refrigerant Pipe Connection
Polythene pipe
Heat-insulation cover
Bendable
Reamer Joint Outdoor
Unit
Outdoor unit dimension
mm(WxHxD)
A(mm)
560
590
624
634
540
673
673
634
634
B(mm)
335
333
366
404
350
403
403
404
404
Mounting dimensions
900x860x315
990x965x345
938x1369x392
845x702x363
946x810x420
946x810x410
952x1333x410
952x1333x415
845x700x320
Air inlet
Air inlet
Air outlet
BH
D
A
W
8
A
B
C
D
Indoor unit
check point
Outdoor unit
check point
Electrical box
(2) The cut-off valves are completely closed before ex-work. Before connecting the refrigerant pipe, be
careful to check whether the valves are completely closed.
(3) The connection procedure of refrigerant pipe: first, unscrew the two valves on the outdoor unit and
the pipe-jointing nut on the indoor unit(please save them care fully). Please connect the refrigerant
pipe according to the manual, the pipe-jointing nut should be screwed tightly and no leakage.
Note: you need two wrenches to make balance.
(4) When the connection of refrigerant pipe is finished, before power on the system, you should
vacuum the indoor unit through the maintenance port on the cut-off valves, or open the high-
pressure valve, and exhaust the air through the maintenance port on the low-pressure valve
(closed). It will take about ten seconds. Then screw the maintenance port on tightly.
(When supplement the refrigerant, fill from the maintenance port of the low-pressure valves on
the outdoor unit ).
(5) Open all the valves completely before power on the system, or it will cause low efficiency.
(6) Gas leak check.
(1) Only the correctly installing of indoor and outdoor unit done, can the refrigerant pipe be
connected.
1. Connecting Of Refrigerant Pipe
Make sure no gas comes from the connections by using leak detector or soap water.
A: Lo packed valve B: Hi packed valve
C and D are ends of indoor unit connection.
Caution
Caution in Handling the Packed Valve
Outdoor unit Refrigerant Indoor unit Flare nut
Stopper
Cap
Valve stem
Valve body
Packed valve
Half union
AC
D
B
Open the valve stem until it hits against the stopper. Do not try to open it further.
Securely tighten the valve stem cap with a spanner or the link.
The bendable pipe should be used on the indoor side;
Bend angel can not exceed 90 degrees;
Bend the pipe in the middle place if possible, as for bend radius, the bigger the better;
The bendable pipe can not be bent for more than 3 times.
Notes for the bendable pipe
PIPE CONNECTION
While bending, expose the pipe by cutting the concave gap on the bending heat-insulation pipe(roll
it with soft band after bent).
To avoid pipe deformation, the radius is the bigger the better.
Use a pipe-bending device to make the compact bending pipe.
Bend the thin pipe
9
Completely shut the cut-off valves of the outdoor unit (as ex-work status). After the refrigerant pipe
has been connected with both the indoor and outdoor unit, let the air exhaust out from the maintenance
gap on the low-pressure cut-off valves of the outdoor unit. Screw the nuts tightly on the maintenance
gap after the air has been discharged.
you should keep the cut-off valves of the outdoor unit completely opened after you have finished the
above steps (step1 or step 2)
,
Before screwing the reamer nut, wipe the pipe and it s surface with refrigerant oil;
After connecting, using soap-water or leakage-checker to make sure there is no leakage occurs;
Use two wrenches to connecting the pipes.
NOTE:
2. Using bronze pipe selling in market
3. To make the refrigerant pipe unblocked completely
Use thumb to curve the pipe
Min. Radius 100 mm
Untie the pipe,
make it straight
Torque wrench
Spanner
Outdoor unit
Indoor unit
The correct refrigerant charging amount to the 5-meter-long pipe of the outdoor unit is marked on the
Product Data Plate. If you have to use longer pipe for every meter plus pipe, the refrigerant should be
added according to the following calculation.
Connective
pipe length
Air purging
method Additional amount of refrigerant to be charged
4. Refrigerant charging
Less than
5m
Use vacuum
pump
More than
5m
Use vacuum
pump
Liquid side: 12.7
PIPE CONNECTION
Liquid side: 9.52 Liquid side: 6.35
R22:(Pipe length-5) X 30g/m R22:(Pipe length-5) X 60g/m
R410A:(Pipe length-5) X 30g/m
R410A:(Pipe length-5) X 60g/m
R22:(Pipe length-5) X 15g/m
R410A:(Pipe length-5) X 15g/m
NOTE:
If you are using a pipe purchased in the market, please make sure the heat-insulation
material is the same as what we supply(at least 12mm in thickness).
Check whether the height drop between
the indoor unit and outdoor unit,the length
of refrigerant pipe,and the max height
drop meet the following reqirements:
Model
R410A
inverter
split air
condtioner
Max. Length
of refrigerant
pipe(m)
Max. drop
height
(m)
Capacity
(Btu/h)
25 10
30 20
50
65
25
30
<15000
>15000~<24000
>24000~<36000
>36000~<60000
Pipe length
10
ΣΥΝΔΕΣΗ ΑΓΩΓΟΥ ΑΠΟΣΤΡΑΓΓΙΣΗΣ
ΣΥΝΔΕΣΜΟΛΟΓΙΑ ΣΩΛΗΝΩΣΕΩΝ
Βαλβίδα πολλαπλής εισόδου
Μετρητής μείγματος
-76cmHg
Μοχλός χαμηλής Μοχλός υψηλής
Λάστιχο εκκένωσης
Λάστιχο εκκένωσης
Αντλία κενού
Μανόμετρο
Βαλβίδα χαμηλής πίεσης
Αγωγός αποστράγγισης εσωτερικής µονάδας
Αγωγός αποστράγγισης
Αγωγός αποστράγγισης Ταινία για την κάλυψη αγωγού
5. Εκκένωση αέρα
Χρησιµοποιώντας αντλία κενού
(Για την µέθοδο που χρησιµοποιεί βαλβίδα πολλαπλής εισαγωγής, ανατρέξτε στο εγχειρίδιο χρήσης της.)
1. Σφίξτε καλά τα παξιµάδια Α, Β, Γ, ∆ , συνδέστε τον σωλήνα της βαλβίδα πολλαπλής εισαγωγής στην
βαλβίδα χαµηλής πίεσης στην πλευρά του ψυκτικού αερίου.
2. Συνδέστε το σωλήνα µε την αντλία κενού.
3. Ανοίξτε πλήρως µοχλό της βαλβίδας πολλαπλής που έχει συνδεθεί η βαλβίδα χαµηλής πίεσης.
4. Ενεργοποιήστε την αντία κενού για να εκκενώσετε τον αέρα. Μετά την έναρξη της εκκένωσης, χαλαρώστε
ελαφρώς το παξιµάδι της βαλβίδας χαµηλής πίεσης στην πλευρά του ψυκτικού αερίου και ελέγξτε ότι
περνάει ο αέρας. (Ο ήχος της αντλίας κενού θα αλλάξει και ο µετρητής µείγµατος θα δείχνει 0 αντί για
µείον.)
5. Μετά το τέλος της εκκένωσης, κλείστε καλά την βαλβίδα
(στην βαλβίδα πολλαπλής) στην βαλβίδα χαµηλής πίεσης και
σταµατήστε την λειτουργία της αντλίας κενού.
Εκκενώστε για περίπου 15 λεπτά και ελέγξτε ότι ο µετρητής
µείγµατος δείχνει -76cmHg ( -1 x 105Pa ).
6.Στρίψτε το στέλεχος της βαλβίδας Β κατά περίπου 45°
δεξιόστοφα για 6-7 δευτερόλεπτα αφού ξεκινήσει να βγαίνει
αέριο κλείστε και πάλι τη βαλβίδα.Βεβαιωθείτε ότι ο µετρητής
πίεσης δείχνει µετρήση λίγο µεγαλήτερη από την
ατµοσφαιρική πίεση.
7.Αφαιρέστε το σωλήνα εκκένωσης από την βαλβίδα χαµηλής
πίεσης.
8. Ανοίξτε πλήρως τα στελέχη των βαλβίδων Β και Α
9. Σφίξτε το κάλυµµα των βαλβίδων.
Βεβαιωθείτε ότι ο αγωγός αποστράγγισης είναι συνδεδεµένος µε την εξωτερική µονάδα µε καθοδική
φορά.
Οι σκληροί σωλήνες PVC (µε εξωτερική διάµετρο 26mm) που διατίθενται στο εµπόριο, είναι κατάλληλοι
για την κάλυψη του συσκευασµένου εύκαµπτου σωλήνα αποστράγγισης.
Ενώστε τον εύκαµπτο σωλήνα αποστράγγισης µε τον αγωγό αποστράγγισης και στερεώστε τα µε ταινία.
Εάν η σύνδεση του αγωγού αποστράγγισης πρέπει να είναι σε εσωτερικό χώρο, για την αποφυγή
συµπύκνωσης σταγονιδίων από την εισαγωγή αέρα, καλύψτε τον αγωγό µε µονωτικό υλικό ( πολυεθυλένιο
µε ειδικό βάρος 0.03 και πάχος τουλάχιστον 9mm) , και στερεώστε τα µε ταινία.
Μετά στην σύνδεση του αγωγού αποστράγγισης ελέγξτε ότι το νερό εξέρχεται από τον αγωγό σωστά και
δεν υπάρχουν διαρροές.
Ο αγωγός ψυκτικού και ο αγωγός αποστράγγισης θα πρέπει να είναι µονωµένοι ώστε να αποφευχθεί η
συµπύκνωση υγρασίας και η δηµιουργία σταγονιδίων νερού.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Inventor V4MFO-66B wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Inventor V4MFO-66B

Inventor V4MFO-66B Bedienungsanleitung - Englisch - 52 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info