7
Clean the entire cabinet of the machine regularly and remove all traces of
soap, etc....
Remove all detergent residue in the soap dispenser with hot water.
Clean the door gasket and remove all detergents and other products.
Shut off the main water, steam and power connections at the end of each
day. Do not change the setting of the water inlet taps on boiler fed machines
once these have been installed.
It is recommended to leave the door and the soap dispenser open after use,
to ventilate the machine.
❐
General maintenance
❐
❐
❐
❐
Maintenance of the machine
The V-belts of the motors should be retightened after two to three months
when first used. This is necessary because these belts are subject to a one-
time stretching when first used. By ignoring this instruction, the belt starts
to slip after a few months and will brake shortly afterwards.
Check regularly if the filters of the water inlet are not blocked by calcifi
-
cation.
If a machine frequently skips the final spin, check whether the probe of the
out of balance switch is still in the appropriate position, that is horizontally
centered and vertically 1/3 from the bottom inside the window. (When the
drum is empty). (See electronic repetition system).
An obstructed drain can cause frequent interruption of spinning for safety
reasons.
❐
Periodical maintenance
❐
❐
❐