CL-305 Click remote control for central locking 1/2 MHK51204
The CL-305 „Click“ remote control system for central locking
The CL-305 “Click” remote control system can be used for the control of an
original central locking control unit, the remote control of powered windows, the
servomotor of a fifth door, boot, etc. The remote control can also be used for
directly controlling servomechanisms. It is suitable for cars with 12V and negativ e
grounding. The main unit is designed for installation in the car interior. It is
protected against reverse polarity and incorrect connector insertion. It is
compatible with RC-4x remote controls. Communication is secured by floating
codes. Up to four remote controls can be enrolled to the receiver.
The CL-305 Click remote control has selectable functions such as re-arming,
selectable pulse lengths, and double pulses. The device can also be used as a
simple security system to prev ent intruders.
Installation:
SIR (y ellow) – siren output, sw itching to ground (max.1.2A).
PGM (blue-white) – programmable output switc hing to ground (max. 300mA),
we recommend providing the P GM output with an RA-12/30A pow er relay.
It can be set to two modes. (se e p ara met er 7 in the ta ble b elo w):
- IMO, the electrical circuits (ignition, fuel pump etc.) of the car can be
immobilized when the car is locked. If the car is unlocked by the remote control
the immobilization relay copies the ignition key.
- BOOT, pressing the button generates a 0.5 sec signal to open the boot.
LCK_IN – NC
ULK_IN – NC
DOOR (grey ) - door switch input. It reacts to connection to ground.
KEY (blue) – ignition key input (+12V).
BLR, BLL (pink) – to confirm locking/unlocking of the car by a confirmation
signal from the turn lights
(+12V, max. load 2 x 5A).
Power supply +12V (red) - connect directly to the battery
GND (black) – connect to the original grounding in the car.
LNO (red-green ), LNC (black-green ), LC (white-green) – pow er locking
relay outputs (max. load 15A pulses).
UNO (red-blue), UNC (black-blue), UC (white-blue) – power unlocking
relay (max. load 15A pulses).
1
8
916
+ 12 V
"1 5 "
+
12 V
rel ay
ma x. 300 mA
sire n
max. 1,2 A
ignition
key
door
contact s
turn lights
max 2x 5A
UC
LC
UN O
UN C
LN C
LN O
inputs
relay output con tacts
unlock ( U) / lock (L)
+
12 V
+
12 V
15 A
PGM
SI R
LCK_IN
KEY
ULK _I N
DOO R
GND
+12 V
LNO
LNC
UN C
UN O
LC
UC
BLR
BLL
C - co m mo n
NO - no rmally ope n
NC - normally close
Alarm function – intruder alarm signaling
The CL-305 Click remote control can be used as a simple car alarm. When the
car is locked and the selectable ALARM function is set to YES , the DOO R and
KEY inputs are monitored. (30 sec after locking the car). If they are activ ated, the
SIR output will be activ ated for 30s and the turn lights will flash for 1 min.
If the car is unlocked by key then the alarm will be triggered. To stop the alarm it
is necessary to unlock remotely. If there had been an intruder alarm during the
time when the car was locked, three siren chirps w ill be heard and the turn lights
will flash during disarming.
Operation
In the factory default setting (PGM output set to IMO mode) button of
the remote control is used to lock the car and button to unlock the car. If
the PGM output is set to BOOT mode, then the button is used for both
locking and unlocking. When pressing the button, a 0.5 sec signal is
generated to open the boot.
Enrollment of the remote controls
Up to 4 RC-4x remote controls can be enrolled to the CL3 05 . All t he c on tr ol s
must be enrolled to the unit in the same session. By enrolling a new remote
control later, all the existing controls are erased.
• Unlock the car and disconnect the CL-305 from its power supply
• Switch the ignition key on, wait for 1 minute and reconnect the power supply.
• During a period of 30 sec. turn the ignition on and off 3 times, in 2 seconds
the turn lights (flashers) will then give a long flash to confirm enrollment
mode entry.
• Press any button on the remote control. Enrolling of the remote control is
confirmed by a turn light flash.
• Enroll all the remote controls (up to four) successively .
• To finish enrolling, switch the ignition key off, the turn lights w ill then flash
long.
Programmable functions
The CL-305 Click remote control has 8 programmable functions, described in
the following table.
To enter programming mode:
• Unlock the car, sw itch the ignition key off and disconnect the
control unit from the power supply,
• After 1 minute reconnect the control unit to the power supply,
• During a period of 30 sec. turn the ignition key on and off 5 times. In
2 seconds the turn lights (flashers) will flash once to confirm programming
mode entry.
• Programming always starts in programming position 1.The status of the
current parameter is indicated by the turn lights (lit or unlit). A parameter can
be changed by pressing the button on the enrolled remote control
• To scroll to the next position switch shortly the ignition key on and
off. The position is indicated by the number of turn light flashes
• To exit programming mode, go through all the parameters and turn the
ignition on and off – it is confirmed by a long turn light flash (otherwise
programming mode will be terminated automatically in 120 seconds)
Specifications:
Power supply 9 - 15 V
Stand-by con sumption 6 mA
Maximum current consum ption 180 mA
Working tempe rature rang e -40 to +85 °C
Enclosur e IP40
Jablotron Ltd. declares, that the CL305 remote control system complies w ith the
essential requirements and other relevant provisions of ECE Regulation No 10
and Directive 1989/336/ES. The original of the conformity assessment can be
found on www.ja blo tron .co m , Technical Support section.
Note: Although this product does not contain any harmful materials
we suggest you to return the product to the dealer or directly to the
producer after use.
Note: Th e bold values in the table are the factory default setting.
Turn lights
Position Function
Unlit Lit
Description
1.
Central locking
ELEC
PNEU
In ELEC mode, the pulse length is 0.5 sec. In PNE U mode, the pulse length is 4 sec. and parameters 2,
3 and 4 have no effect.
2.
WIND
no
yes
To prolong the last locking pulse to 30 sec.- only v alid in ELEC mode. This parameter must not be
set to y es when the servo motors are directly conn ected to the CL-305
3.
DLCK (double
locking pulse)
no
yes
Double locking pulse (first 0.5sec. pulse – 1sec. pause – second 0.5sec. pulse). Only v alid in ELEC
mode
4.
DUNL (double
unlocking pulse)
no
yes
Double unlocking pulse (first 0.5sec. pulse – 1sec. pause – second 0.5sec. pulse). Only v alid in ELEC
mode
5.
REARM
no
yes If the car is not entered w ithin 1 minute after unlocking, it will be automatically locked again.
6.
CHIRP no
y es
Audible siren chirps (if locked one and if unlocked, two chirps can be heard)
7.
PGM
IMO
BOOT PGM output can control the immobilization relay or central locking of a BOOT.
8.
ALARM
no
yes Intruder alarm function