Alarm system JA-60 "COMFORT" - 17 - MDY51319
8.20. Wireless siren alarm sequence: 3 8 x
The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor
siren chirp sounds function if enabled in the siren.
options:
3 8 1 siren enabled
3 8 0 siren disabled
Factory default setting: siren enabled
8.21. Indication of system problems when arming sequence: 3 9 x
The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the user will
be warned with 4 rapid beeps after arming, if any component of the system is not ready for arming. Cause of the problem
(for example permanently triggered detector, lost communication etc.) will remain displayed on the control panel. If the
user ignores this warning, the system will arm after the exit delay, then an alarm will be triggered and finally the problem-
atic item will be bypassed for this arming period. After disarming in such a mode, three beeps will be generated as well.
When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming (for example your main door is not closed), the bypass
of this detector will be canceled automatically and the detector will be ready to trigger an alarm after it is activated (if you
close the door after the system is armed).
options:
3 9 1 warning enabled
3 9 0 warning disabled
Factory default setting: warning disabled
8.22. Control panel splitting sequence: 690 x
The control panel can be split in to 2 independent sections A and B, with a shared common area C. This way the sys-
tem can be operated by two independent user groups. In fact the system in this mode works like two independent sys-
tems. If the system is split to the sections with this setting, it is possible to address detectors, user codes and remote
controls to the above sections (see. 8.22, 23 and 24.).
options:
6 9 0 0 no splitting (partial arming available in this mode)
6 9 0 1 splitting to sections A, B and common C (C is armed only when both A and B are armed)
Factory default setting: no splitting
8.23. Addressing of detectors to sections sequence: 61 nns
If the control panel is split (see 8.21.), the detectors can be addressed to sections by entering:
61 nns
where: nn = wireless detector zone number: from 01 to 16
s = section: 1 = A, 2 = B, 3 = C (common section - it is armed only when both A and B are armed). If the
control panel is not split, and s=2 (or s=3) is selected, this detector will be bypassed while partial arm-
ing.
Example: to address detector zone number 3 to section A enter: 61 031
Factory default setting: detectors 1 - 10 are addressed to A, detectors 11 - 16 are addressed to B
8.24. Addressing of the user codes to sections sequence: 62 nns
If the control panel is split (see 8.21.), the user codes can be addressed to sections A or B by entering:
62 nns
where: nn = user code number: from 01 to 14
s =section: 1 = A, 2 = B
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

jablotron-ja-60

Suche zurücksetzen

  • Kann Anlage nicht mehr scharf stellen! Es leuchtet die Zeichen "F" "Schlüssel" "orange Lampe blinkt"

    Eingereicht am 4-8-2019 17:27

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-60 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-60

Jablotron JA-60 Zusatzinformation - Englisch - 1 seiten

Jablotron JA-60 Bedienungsanleitung - Englisch - 6 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info