554795
1
Zoom out
Zoom in
JA-80P wireless PIR motion detector 1 MHP51803
The JA-80P wireless PIR motion detector
The JA-80P is a component of Jablotron’s Oasis 80 alarm system. It is
designed to detect human body movement inside buildings. The detection
pattern can be modified by optional lenses. Detector immunity has two
selectable levels. The battery-powered detector communicates via OASIS
radio protocol.
Lithium 3.6 V
Installation
Installation shall only be undertaken by technicians holding a certificate issued
by an authorized distributor. The detector can be installed on a flat wall or in
the corner of a room. Avoid objects rapidly changing in temperature, such as
electrical heaters, gas appliances etc. being positioned within its detection
area. Moving objects with a temperature close to that of humans such as
curtains moving above a radiator, and pets should also be avoided. Detectors
should not face windows or spotlights or be near fast-moving air e.g. near
ventilation fans or open windows or doors. There should also be no obstacles
blocking the detector’s “view” of the protected area. Keep the detector away
from metal objects which could interfere with radio communication.
1. Open the detector cover by pressing the tab. Avoid touching the
internal PIR element or damaging the antenna.
2. Remove the PCB which is held by an internal tab.
3. Punch screw holes through the rear plastic cover. At least one screw
should penetrate the tamper-sensitive section.
4. Screw the rear cover to the wall, about 2 metres above the floor
(vertically, with the tab down).
5. Return the PCB to its original place.
6. Leave the battery disconnected and the cover open and then follow
the control panel or receiver manual. The basics of enrollment are:
a. Enter enrollment mode on the control panel by keying in “1” in
Service mode.
b. Install a battery into the detector to activate enrollment.
c. Exit enrollment mode by pressing “#”
To enroll a detector after having already connected a battery, first disconnect
the battery, and press and release the tamper sensor to discharge any
remaining charge to ready the device for enrollment. After installing a battery
into the detector, allow one minute for stabilisation. During this minute the LED
is continuously lit.
DIP switches
NORM / HIGH: selection of immunity to false alarms. The NORM position
combines very good immunity with fast sensor reactions. The HIGH position
gives increased immunity with a slower reaction time and is only used for
problematic installations.
Warning: The most frequent cause of false alarms is bad detector positioning.
DEL / INS: DEL provides entrance & exit delays for detectors installed in a
building entrance. INS allows the detector to instantly trigger alarm activation
if the control panel is armed. This DIP switch (DEL/INS) only has an effect if
the detector has a natural reaction assigned to it in the Oasis control panel.
It also has no effect when used with a UC-8x or AC-8x receiver.
Testing the detector
15 minutes after closing the detector cover, the indicator shows detector
activation. The strength and quality of detector signals can be measured by the
control panel in Service mode.
5 minutes / 1 minute sleep time
To save battery energy, the detector switches to battery-save mode 15 minutes
after its cover is closed. During battery-save mode the detector still always watches
out for movement. The first movement detected is then signalled to the control
panel instantly, and for the next 5 minutes the detector ignores any further
movement. After these 5 minutes, the detector then returns to watching out for
movement until re-triggered. The sleep time can be shortened to 1 minute by
pressing the tamper switch during battery installation. Not pressing the tamper
switch gives a sleep time of 5 minutes.
Battery replacement
The detector monitors its battery voltage and if too low, a transmission is sent to
the control panel to inform the installer or user. The detector continues to function
and shows each detected movement with a flash of its LED. Battery replacement
should not be delayed by more than two weeks. This should be done by a
qualified technician with the control panel in Service mode.
After battery replacement, the detector needs about 60 secs to stabilise during
which its LED lights continuously. After the LED has stopped indicating, test the
detector’s functioning. Expired batteries should not be thrown into the garbage,
but disposed of according to local regulations.
Removing the detector from the system
If a detector is removed, the control panel announces the removal. The
detector has to be deleted in the control panel before intentional removal.
Detection characteristics
The default lens supplied covers an angle of 120° and a distance of 12 metres.
The area is covered by three beams as shown in the following picture.
Side view Top view
The characteristics can be changed by using optional lenses:
JS-7904 Suitable for long corridors. The middle beam covers 20 meters.
JS-7906
Only employs an upper beam with a 120° angle and a 12 metre
range. Ignoring the floor eliminates the effect of the movement of
small pets.
JS-7901
Has a vertical beam forming a wall-like detection barrier which
triggers the detector if someone walks through it.
Note: After changing the lens, test that the desired area is protected. Incorrect installation of the
lens can disable detection.
Auxiliary alarm input
There is an input terminal in the detector
which, among other things, can be used to
detect open doors or windows. Open
circuiting the input has the same effect as
movement in front of the detector
The maximum allowable cable length to
connect a normally-closed sensor to the
terminal is 3 metres. Short circuit these
terminals if the input is not used.
Technical parameters
Voltage: Lithium battery type LS(T)14500 (3,6V AA)
Typical battery lifetime: approx. 3 years (5 min. sleep mode)
Communication band: 868 MHz, Oasis protocol
Communication range: approx. 300m –( open area)
Recommended installation height: 2.0 to 2.5 m above floor level
Detection angle/detection range: 120° / 12 m (with basic lens)
Operational environment according to EN 50131-1 II.indoor general
Operational temperature range -10 to +40 °C
Dimensions 110 x 60 x 55 mm
EN 50131-1,CLC/TS 50131-2-2, EN 50131-5-3 classification: grade 2
Complies with ETSI EN 300220, EN 50130-4,EN 55022, EN 60950-1
Can be operated according to ERC REC 70-03
FCC ID VL6JA80P
Jablotron Ltd. hereby declares that the JA-80P is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC and complies with
part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This
device may not cause harmful interference, and 2. This device must accept any interference
received, including interference that may cause undesired operation.
CAUTION: Changes or modifications no expressly approved by Jablotron could void the user´s
authority to operate the equipment. The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section
Note: Although this product does
not contain any harmful materials
we suggest you return the product
to the dealer or directly to the
producer after use.

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-80P wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-80P

Jablotron JA-80P Bedienungsanleitung - Deutsch - 2 seiten

Jablotron JA-80P Bedienungsanleitung - Holländisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info