terminals should be used for permanent connection between the keypad and
the control panel (see
fig. 7.)
The keypad can also be connected to a bus connector on the control
panel box using a flat cable (max 10 metres) with RJ connectors for the
purpose of servicing or system debugging.
JA-82K control panel installation manual - 5 - MKH51103
1 2 3
A
BC
4 5 6
A
7 8 9
ON
0 #
B
?
OFF
ESC
ABC
OASiS
1 2 3
A
BC
4 5 6
A
7 8 9
ON
0 #
B
?
OFF
ESC
ABC
OASiS
Control and programming
keypad JA-81E
Modular connection
cable
fig. 7 Wired keypad connection
Notes:
When you use the INP keypad hard-wired input to connect the door
detector, its reaction is always delayed (it triggers an entry delay) and it
is assigned to section C.
We recommend having only a single JA-81E hard-wired keypad in the
system.
3.8 Control panel resetting
If you need to set the factory-default settings in the control panel, perform
the following:
1. Disconnect the back-up battery and the mains (using the terminal
board fuse),
2. Connect the RESET link and leave it connected,
3. Connect the back-up battery and the mains,
4. Wait until the green LED starts flashing and then disconnect the
RESET link.
If you need to reset the control panel with preset parameters according to
EN 50131-3 (see 6.48) follow these next steps:
1. Disconnect the back-up battery and the mains (using the terminal
board fuse),
2. Connect the RESET link and leave it connected,
3. Connect the back-up battery and the mains,
4. Wait until the green LED starts flashing and key in the sequence
8080 an finally disconnect the RESET link.
Notes:
After a RESET, all wireless devices and access cards are erased from
the control panel as well as user codes.
The Master code changes to 1234, and the service code to 8080.
If resetting is disabled (see 6.8) it is impossible to reset the control
panel.
4 Control panel power supply
Once the control panel is assembled and all modules are in place, you
can proceed with putting the control panel into operation. We recommend
switching the control panel on without any wired detectors connected, using
only the wired keypad (if it is used in the system) for the first time. Only then
should you continue connecting the detectors. Beware of short circuits – it is
strongly recommended to switch off the power when working.
4.1 Backup battery connection
It is possible to use a 12V gel cell backup battery, with a capacity of up to
2.4 Ah in the control panel. The EN 50131-1 standard requires a 12-hour
minimum backup time in case of a power grid failure. For the standby
consumption of all system devices, see fig. 8.
ATTENTION – the backup battery is sold
charged, avoid shorting out its terminals!
The average backup battery lifetime is up to 5 years after which it must
be replaced. Checking its capacity during regular maintenance is recommended.
The control panel automatically recharges the backup battery and monitors
its condition. When the system runs only on the backup battery, the battery
status is monitored and a technical alarm is triggered before its complete
depletion. The backup battery is then disconnected. Once the power supply
has been restored, the battery reconnects and is recharged.
Ensure that the battery is correctly connected (Polarity: RED = positive +,
BLACK = negative -).
fig. 8 power consumption of individual components
4.2 Power supply connection
Only a person with corresponding electro-
technical qualification can connect the power
supply.
The control panel power supply is double-
insulated (safety class 2) and does not
incorporate a protective grounding wire.
The control-panel power cable should only be installed by a person
holding a sufficient electro-technical qualification.
The control panel power supply is double-insulated (protection class II)
and does not incorporate a protective earth wire.
A double-insulated power cable should be used with a minimum cross-
sectional area of 0.75 to 1.5 mm2. The power cable should be
connected to a switched mains supply fused to 10 Amps.
In the control panel, connect the cable to the power terminals equipped
with a fuse of type T200mA/250V.
Fix the cable firmly to the cable holder in the control panel making
sure that the wire ends are properly secured and connected in the
terminals.
Mains fuse
T 200 mA
4.3 Powering-up the control panel for the first time
1. First check all the wiring, and if a GSM communicator is installed, insert its
SIM card (PIN code disabled).
2. Check the backup battery connection
3. Switch the power supply on – a green LED starts flashing on the control panel
board.
4. If a hard-wired keypad is connected it indicates “Service” mode
5. The control panel can also be set up via the interface using OLink software
(A virtual keypad can be used in OLink to indicate system status).
6. If you have neither the wired keypad, nor OLink, enrol a wireless keypad by
the following means:
a) have an opened keypad and its battery ready,
b) check that the green LED in the control panel is flashing,
c) short the RESET link in the control panel for 1 second (enrollment
mode opens),
d) install batteries into the keypad not far from the control panel
e) the keypad emits a beep and enrols to the first free address. After
that it displays “Enrollment” and offers another free address for
enrollment
device mA note
JA-82K control panel 30 without a communicator
JA-82R module 20
JA-82C module 15
JA-81E keypad 30
JA-81E RGB keypad up to 100
JA-80H (N) keypad 60 including WJ-80 interface
JA-8xY communicator 35
JA-80V communicator 30
JA-80X communicator 15
Wireless devices are not powered from the control panel
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

jablotron-ja-82k-oasis

Suche zurücksetzen

  • Rauchmelder schlägt Alarm ohne Rauch, kann das am Akku liegen? Eingereicht am 29-8-2018 09:05

    Antworten Frage melden
  • Wie kann ich einen irrtümlichen Sabotaschealarm im System neutralisieren?
    Danke Hubert Eingereicht am 21-7-2017 17:57

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-82K OASIS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-82K OASIS

Jablotron JA-82K OASIS Installationsanweisung - Deutsch - 23 seiten

Jablotron JA-82K OASIS Bedienungsanleitung - Englisch - 23 seiten

Jablotron JA-82K OASIS Zusatzinformation - Englisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info