12 Control panel programming sequences
Function Sequence Options
Factory
default
Setting to
comply with
EN-50131-1
Notes
Entering enrollment mode
One wireless device (detector, keypad, key
fob, siren or sub control panel) can be enrolled
to each address from 01 to 50.
The system offers vacant addresses one by
one, if all addresses are occupied no devices
can be enrolled.
A device enrolled to address 01 to 30
disables the corresponding hard-wired input
01 to 30.
In addition to enrollment mode, devices can
also be enrolled by keying in their production
codes (see 6.42).
1
Keys:
1 and 7 address scrolling
holding 2 erases the
displayed address
holding 4 erases all
addresses
# exiting enrollment
mode
nothing
devices enroll by connecting
their power (battery) except
keyfobs which enroll by
pressing & holding a pair of
their buttons
an occupied address is
indicated by the A indicator
being lit
enrolling a device to a new
address will move it there
Exit delay time
20x
x = 1 to 9 (x10 s =10 to 90 s)
30s
Entrance delay time
21x
x = 1 to 9 (x 5 s = 5 to 45 s)
20s
if a final door detector is used,
then x is multiplied by 30s
instead (i.e. from 30 to 270s)
Alarm duration time
22x
x = 1 to 8 (min.), 9=15min
4 min.
0=10s (for testing)
PGX function
7
on/off
80/81)
PGY function
23x
24x
x in an unsplit system:
0 whole system set (ABC) =
PG on
1 any system part set = PG on
2 AB set (not C) = PG on
3 Fire alarm = PG on
4 Panic alarm = PG on
5 Any alarm = PG on
(excluding Panic)
6 AC dropout = PG on
7 PG on/off (by 80 /81 for
PGX and 90/91 for PGY)
8 Single 2 s pulse
(keys 8 = X, 9 = Y)
1
any
system
part set
x in a split system
0 alarm A = PG on
1 alarm B = PG on
2 entrance delay A = = PG on
3 entrance delay B = PG on
4 A set = X on, B set = Y on
5 A panic = X on,
B panic = Y on
6 Fire = X on,
AC dropout = Y on.
7 PG on/off (by 80 /81 for
PGX and 90 / 91 for PGY)
8 - Single 2 s pulse
(keys 8 = X, 9 = Y)
Enablement of telephone number changes in
maintenance mode
25x
251 = YES 250 = NO
NO
see communicator
Radio interference indication
26x
261 = YES 260 = NO
NO YES
30s or longer
Radio communication supervision
27x
271 = YES 270 = NO
NO YES
RESET enabled
28x
281 = YES 280 = NO
YES
Master control panel enrollment to a sub
control panel for setting (arming) control
290
The sequence triggers
enrollment.
(Un)setting the master
control panel will (un)set the
sub control p.
The sub c. panel must be in
enrollment mode.
Master code reset
291
Returns master code to 1234
It has no effect on other
codes and it is recorded in
the control panel memory
Measuring signal strength
298
Activates measurement
arrow keys scroll addresses,
# halts measurement.
Enrolling the control panel to UC, AC or a
sub control panel
299
The sequence triggers
enrollment.
see 6.9
Setting (arming) without an access code
30x
301 = YES 300 = NO
YES NO
by keying: A, B, ABC, 1, 2,
3,4
Triggered detector indication
by text on the keypad display
31x
311 = YES 310 = NO
YES
allows the display of open
windows & doors,
to view details press ?
Confirmation of intruder alarms
In this mode, the triggering of an intruder detector in
a set (armed) section will only be recorded to the
memory as an unconfirmed alarm and if then
followed by the activation of any other intruder
detector within 40 minutes, an alarm will be
triggered. If the first triggered detector has a DEL
reaction and it is not confirmed by any other detector,
it will not trigger an alarm after the entrance delay
has expired.
32x
321 = YES 320 = NO
NO
An alarm can be confirmed by
any other intruder detector in any
section which is set (armed).
Exit delay beeps
33x
331 = YES 330 = NO
YES
The last 5 s faster
Exit delay beeps while partially arming
34x
341 = YES 340 = NO
NO
The last 5 s faster
(linked to 33x setting)
Entrance delay beeps
35x
351 = YES 350 = NO
YES
Setting (arming) confirmation by wired-siren
chirp
36x
361 = YES 360 = NO
NO
IW terminal only
Siren always sounds during audible alarms
37x
371 = YES 370 = NO
YES
NO = siren only sounds if the
system is completely set (armed)
fig. 18 Summary of the programming sequences
JA-82K control panel installation manual - 17 - MKH51103
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

jablotron-ja-82k-oasis

Suche zurücksetzen

  • Rauchmelder schlägt Alarm ohne Rauch, kann das am Akku liegen? Eingereicht am 29-8-2018 09:05

    Antworten Frage melden
  • Wie kann ich einen irrtümlichen Sabotaschealarm im System neutralisieren?
    Danke Hubert Eingereicht am 21-7-2017 17:57

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-82K OASIS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-82K OASIS

Jablotron JA-82K OASIS Installationsanweisung - Deutsch - 23 seiten

Jablotron JA-82K OASIS Bedienungsanleitung - Englisch - 23 seiten

Jablotron JA-82K OASIS Zusatzinformation - Englisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info