4. Detector and accessory installation
a) Install the JA-60N magnetic detector onto the door
(antenna pointing up or down)
b) Install the JA-60P PIR motion detector
c) Select Instant or Delay reactions via the DIP switches
inside the detectors.
d) Connect the detector’s batteries (pull out the red tape to
activate the batteries)
e) Attach the keypad to the desired location
f) Plug the UC-260 wireless siren into a power socket
g) Test the wireless doorbell button and install it.
5. Enrollment of additional accessories
If you install additional detectors (max. 32), you have to enroll
them. The system should be in P mode (if not enter F0 6060):
a) Press 1 to enter enrollment mode*
b) The next free detector position will be displayed on the
keypad.
c) Install batteries into all new detectors step by step to enroll
them (system will automatically offer the next free position)
d) To scroll through sensor positions, press 1 (up) or 7 (down)
e) To enroll a second detector to an occupied position press 5
before you install the detector’s batteries
f) To exit enrollment mode press the N key
The wireless keypad (JA-63F) enrolls after you install its
battery while in enrollment mode.
The remote control (RC-4x) enrolls after you press and hold
both
and buttons while in enrollment mode.
The wireless outdoor siren (JA-63A) enrolls after it is
powered up while in enrollment mode
To enroll the control panel to UC receivers enter 299 on
the keypad while in P mode
Check individual device manuals for more details
*Enrollment mode will also start after shorting the reset pins
in the control panel while it is in P mode.
6. Detector and controller testing
a) The system should be in P mode (if not enter F0 6060)
b) Trigger detectors – their addresses (1=door and 2=PIR) should
be indicated (if the PIR detector does not react, re-enter test
mode by opening and closing its cover)
c) Press button
on the RC-4x remote control c2 will be
indicated
7. To measure the strength of the radio signal
a) While in P mode, press 1 and then using 7 scroll to position 1
b) Press 8 to start measuring
c) Activate the door detector to view its signal strength
d) Using the 1 key, scroll to the next position (2 PIR) and
check its signal strength (if the PIR detector does not react,
reenter its test mode by opening and closing its cover)
e) Repeat step d) to check all enrolled items. The wireless keypad
(c1) signal is indicated after you trigger its tamper. The remote
control (c2) is indicated after you press it’s
button.
f) Change the location of an item if its signal is lower than 2
g) Return to P mode by pressing the N key
8. Programming the system
a) The system should be in P mode (if not enter F0 6060)
b) Using the following sequences you can program:
Function Sequence Comments
Your installer code* 5 xxxx xxxx
6060 factory default
xxxx new code
Exit delay
20x
3=30sec factory def.
Entrance delay
21x
3=30 sec factory def.
Alarm duration
22x
4=4min factory def.
Time & date
4 hh mm DD MM YY
See control panel installation manual for more details.
Must be changed
9. Finishing the installation
a) Fill in the information on the sticker label and attach it inside
the keypad cover.
b) Switch the system to standby (by pressing the N key)
c) Instruct the user on how to operate the system
A
attach
C
open
B
click
rear tamper
lever
Don't tight
this screw
2
2,5
1,5
1
0,5
1,6 3,7
12
range
[m]
height
[m]
120
ş
1
2
m
zone A
zone B
zone C
zone A
zone B
zone C
JA-60P coverage
avoid locations against windows or close to a heater
JK-16 PROFI 3/4 MGK24401
10. Keypad operation
11. Specifications
Power 230 VAC, max 0.1 A, supervised, class II
Power supply A type (EN 50131-6)
Backup battery 12 V, 2.26 Ah, normal life time 5 years
Backup power output 13VDC, the max. permanent current is 0.4
or 1A for max. 15 min (1 cycle per hour),
Consumption of the control panel is 30 mA; JA-60E 25 mA
Hard-wired inputs 4 input zones, selectable triggering:
Wireless zones 16 zones (2 detectors can be enrolled to each
Wireless controllers max. 8 (JA-60F, RC-22, RC-44)
Access codes master code and 14 user codes.
Wired outputs Alarm relay dry contacts 1A/60V;
Programmable outputs PgX , PgY connect to the GND max. 0,1 A
Siren output 12 V, 0.7 A
Working frequency* 433.92 MHz; digital hopping code; supervised
communication
Comply with EN 50131-1, EN 50131-6
Security grade 2 (low to medium risk)
Environmental class II indoor – general (-10 to 40oC)
Safety EN 60950-1
EMC ETS 300683
Radio characteristics ETSI EN 300220
Can be operated according to ERC REC 70-03
Jablotron Alarms a.s. hereby declares that the JA-83K “OASiS“
control panel is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not
contain any harmful materials we suggest you to return the
product to the dealer or directly to the producer after usage.
Entry Function
User code
Arming / Disarming (Setting\Unsetting)
F1 /
Arming without a code
F2 /
Partial arming
F3 /
Door lock opening
F4
Memory reading
F5 New master code (example: F5 1234 2789 2789)
F6 User codes setting (example: F6 1234 03 3344)
F7 /
Disarming under duress
F8
Appliance control (F81 = ON, F80 = OFF)
F0 M.code
User test mode (example F0 1234)
N
Escape & fault detail reading
Motion detector
JA-60P
Doors, Windows
JA-60N
Wireless keypad
JA-63F
Remote control
RC-4x
Indoor siren
UC-260
(230 V AC)
Control panel
JA-63KR
Power (230 V AC)
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JK-16 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info