Wireless Control Receiver UC-216 1/2 MEJ52103
Wireless Control Receiver UC-216
Description
The UC-216 is a three channel receiver of coded radio signals. The status
of its two output relays and its output transistor is indicated on the front
panel. Up to 20 remote controls (RC-11, RC-22) can be taught to the unit.
There are three different operating modes available for the remote controls.
This allows the UC-216 to be used as a control for an alarm system, for
remote gate opening, garage door control, panic switch etc. A floating code
ensures a high security of transmission.
The UC-216 can also be used as a receiving unit for JA-60 wireless
system items. This use, for example, allows an existing wire-operated alarm
system to be extended with additional wireless detectors, wireless access
control keypads, etc.
Specifications:
Operating voltage: 12-24 V DC or 15 V AC
Power consumption: standby 0.25 W
max. 1 W (both relays activated)
Operating frequency: 433.92 MHz
Coding: digital, each remote control or JA-60 item has
a unique floating code
Output relays: Max. 120 V / 1 A
Output transistor: Max. 40 V / 0.2 A
Range (open area) : with RC-11 up to 30 meters
with JA-60 items, up to 100 meters
Working temperature from -10 to +40°C indoor use only
Can be operated according to ERC REC 70-03
Hereby, Jablotron Ltd., declares that this UC-216 is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Installation:
Open the external cover of the unit by pressing in the internal tab of
the lock on the top (small flat screw-driver is appropriate). Loosen the
central screw and remove the PCB. Route the wires through the hole in
the bottom of the rear housing. Attach the housing to the desired place
using the provided screws.
Terminals description:
TAMPER tamper switch output (max. 24 V / 100 mA)
OUT output of NPN transistor to GND
NC, NO, C output relay dry contacts (X and Y)
+U, GND power voltage 11-24VDC or 15VAC
The status of relay X, relay Y and the OUT is indicated by 3 LED
indicators on the front cover. When active, the corresponding LED
lights.
RC-11, RC-22 mode
Remote controls enrolling - you can
enroll up to 20 different RC-11 or RC-22
remote controls to the UC-216 unit. There
are two buttons on each remote control
(A and B), enabling each remote control
to send two different commands by
pressing button A or B. The RC-11 can
also send a third command by pressing
the A & B button simultaneously (not
available with the RC-22).
There are two setting buttons in the
UC-216. Button X is used for relay X
teaching; button Y is used for relay Y
teaching. By pressing the setting button
you can scroll through the three learning
(operating) modes (1 to 3) indicated by a
corresponding flashing indicator.
By pressing a button on the remote
control while a desired UC-216 learning
mode is selected, you enroll that button to
the receiver’s memory. The corresponding
operating mode will now be associated
with this remote control button.
Operating modes available (valid for X and Y relays)
MODE reaction of the relay
when RC button pressed
which RC
button can be
taught
1 pulse
relay will turn on for 2 seconds A, B, A&B
2 latch
relay status will change to the
opposite (ON/OFF/ON...)
A, B, A&B
3 ON - OFF
button A turns relay on, button B
turns relay off
A or B
Setting remarks
new RC button enrollments are added to previously enrolled ones
after 20 RCs are taught, no other remote can be added
double flashing of the LEDs indicates a full memory
if one button is taught for multiple modes, only the last taught mode
will remain in the UC-216’s memory
you can combine different modes with different RC buttons
the output OUT can be activated only by simultaneous pressing of
the A&B buttons on the RC-11, only if the A button was enrolled for
relay X and the B button for relay Y. The OUT mode is the same as
the selected mode of relay X. This way three independent outputs
can be controlled.
A selected setting mode will close after an RC button is enrolled,
or automatically after 10 seconds.
All UC-216’s can operate with only remote controls or JA-60 items.
Combined operation is not available.
Note: A remote control taught to the UC-216 can also be used for
other devices. For example: the remote control of Jablotron’s Accent car
alarm can not only control your car with buttons A and B, but can also
control another device, if the simultaneous pushing of A&B buttons has
been taught to a UC-216 controller.
Garage door or gate opener mode
The UC-216, in combination with RC-11
or RC-22 remote controls, has an optional
mode to control garage door or gate
actuators. This mode is only available when
the UC-216’s memory is erased. By
pressing the UC-216’s X setting button,
scroll until both LED’s 1 & 2 are
simultaneously flashing. Then, by pressing
any button of the remote control, you teach
it to the UC-216.
A
B
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron UC-216 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info