Replacement of battery
The mounting plate makes it easy to pull down the smoke alarm for cleaning and
for replacement of the battery. As an extra safety precaution, the smoke alarm
cannot be mounted without a battery. The smoke alarm requires one 9 VDC
battery (included – mounted in the battery-compartment).
Please note: At first time installation simply remove the plastic strip between the
terminals and the contact before mounting the smoke alarm.
Note: For optimal detection the smoke alarm should be installed in a suitable
location as described above.
After mounting and after every battery change, test the smoke alarm by pressing
the red test button until a penetrating, clear signal is heard. Make sure that the
red test button flashes once a minute. When the alarm is set-off, a penetrating,
rapidly pulsating signal is given out (min 95 dB/1m). The alarm can be stopped by
pressing the red test button.
Maintenance
The following guidelines will help you care for the JACOB JENSEN
TM
Smoke Alarm
so that you can enjoy using it for many years.
1. Test the smoke alarm once every month – preferably once every week e.g.
when doing the vacuuming. This can be done by pressing the red test button
for at least 10 seconds or by blowing smoke into the alarm.
2. Always test the smoke alarm when returning from a vacation or a trip.
3. Clean the smoke alarm regularly by wiping with a soft cloth or vacuum
carefully. Do not immerse the smoke alarm in water.
4. The lifetime of the battery is approx 1 year.
Approximately one month prior to the battery running flat, the alarm beeps
briefly once every minute. The alarm is still functioning but the signal indicates
that the battery needs to be replaced. The battery has to be 9V of a good
quality 6F22 or 6LR22 e.g. Duracell MN 1604 or Energizer 522. Always test the
smoke alarm after changing the battery.
Specifications
Operating temperature: 0° C to + 40° C
Operating humidity: Max. 85 %
Battery: 1 x 9 VDC type 6F22 or 6LR22
Life expectancy: 12 months
Radioactive material: Americium-241, activity 37kBq
Disposal: As household refuse or by returning the smoke
alarm to the importer.
Life expectancy: Replace the product after 10 years.
Guarantee and Conditions
The manufacturer of this product guarantees (battery excepted) that the
product is free from material and manufacturing defects. This only applies if
the alarm is used in the normal way and maintenance carried out regularly. The
guarantee is also conditional on the smoke alarm not having been modified or
subjected to attempted repairs. Your statuary rights as a customer are in no way
compromised by this guarantee. The manufacturer and its suppliers accept no
liability whatsoever for any damage, expense, loss of profits or any other damage
incurred as a result of using this product. In the event of a defective smoke alarm,
please return to the place of purchase or to the importer.
Manufacturer: Homewatch Ltd.
Importer:
Bell Xpress A/S, Sletvej 50, DK-8310 Tranbjerg J
mail@bellxpress.dk – www.bellxpress.dk
Prior to fire
Plan and practise an escape route.
Agree a place to meet and remember that a smoke alarm does not put out a fire.
Is fire-fighting equipment available in your home? Remember that even a small
amount of smoke can be fatal.
In case of fire
Save – warn – put out
1. Warn anyone who might be in danger.
2. Notify the fire brigade. Always keep the number for the fire brigade by the
telephone.
3. If possible, try to put out the fire with your fire fighting equipment. Isolate
the fire by closing doors and windows to the room on fire. Any closed door to
the room on fire can prevent the fire from spreading.
4. Make sure that someone is available to guide the fire brigade when they
arrive.
If you are unable to get out of the house - go into a room with windows
facing the road, close the door and shout out for help. Don't waste time
trying to pick up valuables or possessions, your life is more important.
5. Always close the doors behind you.
6. Use towels, sheets or clothes to block any gaps under the door to help stop
smoke spreading into the room.
7. Where smoke is dense, get down to the floor where the smoke is not usually
so thick as smoke rises.
8. Cover your mouth and nose with a damp cloth.
9. Stay calm - do not panic.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jacob Jensen Smoke Alarm S1201 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info