2-7
2
Range selection
Changes the radar range.
“+”: Increases the range by one step. (The maximum range is 96 or 120 nautical miles.)
“-”: Decreases the range by one step. (The minimum range is 0.125 nautical mile.)
RINGS indicator selection
Turns on and off the fixed distance scale display. When this is turned on, the intervals of the
range rings will be displayed. When this is turned off, then “OFF” will be displayed.
Pulse width selection
Select the pulse width. There are three pulse widths: Short pulse (SP), middle pulse (MP)
and long pulse (LP). The pulse widths that can be used depend on the range being used. If a
change cannot be made, then nothing will be displayed. This setting is stored for each range.
Tuning indicator mode
Sets the tuning mode to MANUAL or AUTO.
MANUAL AUTO
Manual tuningAutomatic tuning
Bearing mode selection
This has the same function as the [AZI MODE] switch. It switches between North-up (true
bearing), Head-up (relative bearing) and Course-up. Each time this button is clicked it will step
through the settings in the following order: “N UP” “C UP” “H UP”
Motion mode selection
The screen display is changed between the True Motion (TM) and Relative Motion (RM)
displays. Clicking this button will switch between “TM” and “RM.” (R) indicates a relative trail.
(T) indicates a true trail.
Transmission/Standby selection
About three minutes after the [PWR] switch is turned on, the “PREHEAT” indication on the upper
left of the screen will change to “STANDBY.”
STANDBY: Indicates that the unit is in the standby state. Clicking the switch at this time will
change the unit to the transmission state.
TRANSMIT: Indicates that the unit is in the transmission state. Clicking the switch at this time
will change the unit to the standby state.
Change Interswitch connection
This is displayed if Interswitch is connected. The indicator shows the connected scanner and
the connection status of the indicator. When this switch is pressed, a menu to change the
connection states of the scanner and indicator will be displayed. The scanner and indicator
connection states cannot be changed, unless the master indicator is in the standby state.
AIS target refreshed (ACT)
When this switch is pressed, the AIS target will be activated.
AIS target deactivated (DACT)
When this switch is pressed, the activated AIS target is paused.
ARPA symbol indicator selection
Turns the ARPA symbol indicator on or off. The setting is changed each time this button is
clicked.
AIS symbol indicator selection
Turns the AIS symbol indicator on or off. The setting is changed each time this button is
clicked.
67

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für JRC JMA9932SA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info