487875
13
Zoom out
Zoom in
Vorherige Seite
1/76
Nächste Seite
Copies of the I/B. Please reproduce them without any
changes except under special instruction from Team
International BELGIUM. The pages must be reproduced
and folded in order to obtain a booklet A5 (+/- 148.5 mm
width x 210 mm height). When folding, make sure you
keep the good numbering when you turn the pages of
the I/B. Don’t change the page numbering. Keep the
language integrity.
13 TKG SFC 1001 - 100525
Assembly page 13/76
Fax +32 2 359 95 50
STORAGE OF ACCESSORIES:
In the base of the appliance there is a compartment in which you can store the accessories.
Separate the water tank from the base by pressing the button at the back of the appliance
near the right wheel and lifting the water tank upwards by the handle at the same time.
When you have stored the accessories or taken out the desired accessory, put the water tank
back on the base of the appliance. Press down firmly until it clicks into place.
OPERATION:
CAUTION! This appliance should not be used directly on soft plastics, non-pretreated wood or
cold glass.
Steam could damage the furniture surface. For a safe work please execute a test
run beforehand. Pay attention to the instructions for maintenance of the
manufacturer.
ASSEMBLY:
(DO NOT ATTACH THE APPLIANCE TO THE POWER SUPPLY UNTIL YOU HAVE CHOSEN AND
ATTACHED AN ACCESSORY.)
Warning! After use, unplug the appliance from the mains supply socket and press the steam
button to reduce the internal pressure sufficiently. Then you can release the safety cap.
1. Take the desired accessory from the storage compartment and put the water tank back
on the base of the appliance (see section “STORAGE OF ACCESSORIES”).
2. Attach the flexible hose with the steam gun to the appliance. To do so, flip down the flap
that covers the hose connection inlet and insert the hose connector into the hose
connection inlet until it locks, making sure that the small lug of the hose connector enters
into the small slot at the bottom of the hose connection inlet. You may press the release
buttons on the sides of the hose connector to facilitate the entering of the hose connector
into the hose connection inlet. To remove the hose after use, press the release buttons on
the sides of the hose connector and pull at the hose connector.
3. Unscrew the safety cap. To do so, press the safety cap and at the same time turn it
anticlockwise (if there is still water in the tank and if the safety cap was still screwed in tight
for a previous use, some degassing will occur. This is normal and not dangerous).
4. Fill the water tank with water. Please use the provided measuring cup and the funnel. Do
not exceed the maximum filling level (1.4 litres). If the water in your region is hard, it is
advisable to use distilled water or in that case you can also use tap water that has been
boiled beforehand.
5. Note: never fill descaling agent, perfume or detergent into the water tank, in order to
avoid damages to the appliance.
6. Screw back the safety cap. To do so, press the safety cap and at the same time turn it
clockwise.
7. If you want to clean floors or areas which are difficult to reach, assemble the extension
tubes. To do so, push the open end of a tube onto the steam gun until the release button
of the steam gun clicks into place. You can assemble just one, two or all three extension
tubes. To take the extension tubes off after use, press the release button on top of the
extension tube or steam gun and pull the tubes apart.
8. Put the floor brush on the extension tube until the release button clicks into place if you
want to clean floors. If you want to use another accessory, you first have to assemble the
accessory connecting piece: slide the accessory connecting piece onto the steam gun or
onto the extension tube until the release button clicks into place. Then assemble the
straight nozzle onto the accessory connecting piece and give the straight nozzle a quarter
turn in an anti-clockwise direction to lock it into place. To take the straight nozzle off after
use, give it a quarter turn in a clockwise direction and pull it off. To take the floor brush or
the accessory connecting piece off after use, press the appropriate release button and
pull it off.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kalorik TKG SFC 1001 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info