– 3
Î Mount the nozzle on the spray pipe (mark-
ings on the adjustment ring at the top).
Î Install spray pipe on the hand-spray gun
with pressure and volume regulation.
Note (for 1.524-207 only)
When space is limited, the enclosed adapt-
er with nozzle can be mounted directly to
the hand spray gun.
Î Fasten the high pressure hose to the
high pressure connection.
Î Insert the crank in the hose drum shaft
and lock it in.
Î Before rolling up, stretch out the high
pressure hose.
Î Wind the high pressure hose in uniform
layers on the hose drum by rotating the
crank. Select the rotation direction in
such a way that the high pressure hose
does not get bent.
Danger
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the
socket outlet is (see technical specifications).
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
Unsuitable extension cables can be haz-
ardous. Only use extension cables out-
doors which have been approved for this
purpose and labelled with a sufficient cable
cross section:
For connection values, see type plate/tech-
nical data.
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
Î Connect the supply hose (minimum
length 7.5 m, minimum diameter 1“) to
the water connection point of the appli-
ance (such as the tap).
Note
The supply hose is not included.
Î Open the water supply.
Attaching the Accessories
In devices without hose drum:
In devices without hose drum:
Start up
Electrical connection
Water connection
Connection to the water supply
20 EN
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher HD 9-19 M Plus wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info