726307
29
Zoom out
Zoom in
Vorherige Seite
1/396
Nächste Seite
- 13
ATTENTION
Always keep the installation site of the sys-
tem well ventilated to protect the machine
against over-heating.
The appliance should not be directly at-
tached to the network of water and high
pressure pipes. It is mandatory to install
the connecting hoses.
A shut-off tap must be installed be-
tween the main water supply and the
connecting hose.
For installation, please follow the specifica-
tions of the VDMA sheet 24416 "High pres-
sure cleaners; fixed high pressure cleaning
systems; concepts, requirements, installa-
tion, testing" (the German version can be
procured from Beuth Verlag, Cologne,
www.beuth.de).
The pressure loss in the pipe connec-
tions must lie below 1.5 MPa.
The completed pipe connections must
be checked using 32 MPa.
The insulation of the pipes must be re-
sistant to temperatures until 100 °C.
ATTENTION
Risk of damage to the plant if water supply
is not of suitable quality.
Note: Impurities in the inlet water can dam-
age the unit. Kärcher recommends a water
filter with a mesh width of < 80 μm.
Quality requirements for tap water:
* Test volume 1litre, Settling time 30 min-
utes
** decalcification measures are necessary
if the values are higher
The water inlet is to be connected to the
main water supply using a water hose.
The water supply must have a minimum
output of 4000 l/h for HDC 40/XX,
6000 l/h for HDC 60/XX, 8000 l/h for
HDC 80/XX at minimum 0.15 MPa.
Appliances without prepressure pump:
The water temperature must lie below
60 °C.
Machines with prepressure pump: The
water temperature must lie below 85
°C.
Note: Operating procedures create short
term power sinkings. During unfavorable
net conditions other devices might be dis-
turbed.
ATTENTION
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to IEC
60364-1.
Current-carrying parts, cables and ap-
pliances in the working area must be in-
stalled in a defectless state and must be
protected against water sprays.
DANGER
To avoid accidents due to electrical faults
we recommend the use of sockets with a
line-side current-limiting circuit breaker
(max. 30 mA nominal tripping current).
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
5.957-926
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2016/04/01
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
Installing the plant
Only for authorised techni-
cians!
Assembly
Installing the high pressure
connections
Water supply
pH value 6,5...9,5
electrical conductivity < 2000 μS/cm
removable materials < 0.5 mg/l *
filterable materials (grain
size below 0.025 mm)
< 20 mg/l
Hydrocarbons < 20 mg/l
Chloride < 300 mg/l
Calcium < 85 mg/l **
Total hardness < 15 °dH **
Iron < 0.5 mg/l
Manganese < 0.05 mg/l
Copper < 0.02 mg/l
free of bad odours
!
Electrical connection
EU Declaration of Conformity
Product: High pressure cleaner
Type: 2.509-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
Applied harmonized standards
EN 60335–1
EN 60335–2–79
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 2015
EN 61000-6-4: 2007
EN 61000–6–2: 2005
EN 61000–3–11: 2000
EN 61000–3–12: 2011
Warranty
CEO Head of Approbation
29EN
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher HDC 60-16 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info