The water flows back from the swimmer
tank to the suction side of the pump. The
water level in the swimmer tank is kept con-
stant by the swimmer valve. In case of fail-
ure of the swimmer valve, the water exits
via the overflow. If the water supply is dis-
turbed, the lack of water fuse will send an
error message to the controls.
The electric engine will drive the crankshaft
pump. The pump transports the water un-
der high pressure to the pressure side.
The high-pressure water reaches the high-
pressure output via the overflow valve and
the pressure sensor. After that, there will be
the high-pressure network of the operator.
Remaining water will be routed back to the
floater basin by the overflow valve. If all
consumer loads have been switched off,
the overflow valve will completely switch to
backflow to the floater basin. If the pressure
at the output exceeds the maximum operat-
ing pressure at the output, the safety valves
will open.
The appliance will be switched to
READY mode by activating the release
switch. If the pressure in the systems
sinks below the determined switch-on
point due to the opening of a hand
spray gun, the high-pressure pumps will
be switched on.
If the flow switch at the overflow valve is
triggered while the high-pressure
pumps are running after closing all
hand sprayguns, the pump is switched
off once again with a 30 second delay.
If the system is ready and the high-
pressure pumps are not turned on, a
timer is started, which will reset the
readiness of the unit after 6 hours.
Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
The safety mechanism against lack of wa-
ter prevents the high pressure pumps from
being switched on when there is no water.
The temperature sensor switches off the
appliance as soon as the water tempera-
ture is too high.
The winding protection contact in the motor
winding of the pump drive switches off the
engine when there is a thermal overload.
The safety valve opens when the over-
flow valve is defective.
The safety valve is set by the manufac-
turer and sealed. Setting only by cus-
tomer service.
If all hand spray guns are closed, the
overflow valve opens and the entire wa-
ter volume will flow back into the floater
basin. The high pressure pumps are
switched off via the flow switch once the
set delay time has elapsed.
The remaining water flows back into the
floater basin via the overflow valve.
If the hand spray gun is opened again, the
high pressure pumps will restart via the
pressure sensor for high pressure.
Water inlet
Pumps
High pressure side
Pressure regulation
Controls
Safety Devices
Safety mechanism against lack of
water in swimmer tank
Temperature sensor
Winding protection contact
Safety valve
Overflow valve with flow switch
Pressure sensor for high pressure
19EN
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher HDC 80-8H wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info