726293
26
Zoom out
Zoom in
Vorherige Seite
1/376
Nächste Seite
- 10
Fault Possible cause Remedy of whom
Appliance is not running There is no voltage in the machine. Check electrical mains. Electrician
Motor protection switch for the con-
trol has been triggered.
Check motor protection switch. Customer Service
Pump starts during the stand-by
period and not when the hand
spray gun is opened.
Pressure sensor for high pressure
or cable to pressure sensor defec-
tive.
Replace pressure sensor or cable. Customer Service
Full pressure does not build up
in the appliance
Flushed the nozzle. Replace the nozzle. Operator
Suction site pipe leaking. Check screw fittings and hoses. Operator
Safety valve is leaky. Check the setting; install new washers, if re-
quired.
Customer Service
Overflow valve is leaking or set too
low.
Check valve parts; replace damaged parts;
clean the dirt.
Customer Service
Valve in the pump defective, high-
pressure solenoid valve does not
close.
Replace defective components. Customer Service
High pressure pump is knock-
ing; manometer is swaying wild-
ly
Pump is sucking air. Check suction system and remove leaks. Operator
Valve plate or valve spring is defec-
tive.
Replace defective components. Customer Service
Advance pump calcified or defec-
tive.
Check advance pump. Operator
Overflow valve opens and clos-
es continuously during 0 takeo-
ver
Leakage in the high-pressure pipe-
line system or hand spray gun leak-
ing.
Locate and seal leakage. Operator
Backflow valve or control piston
seal leaking in overflow valve.
Repair the overflow valve. Customer Service
Error code 01 is displayed Control board defective, green
LEDs are not blinking.
Check control board, replace if necessary. Customer Service
Error number 10, 11, 12, 13 is
displayed
Overflow protection switch of the
respective high pressure pump has
been triggered.
Rectify cause for over-loading. Customer Service
Error code 14 is displayed Motor protection switch has been
triggered or frequency inverter not
ready.
Rectify cause for over-loading. Customer Service
Error number 18, 19, 20, 21 is
displayed
Thermal sensor of the respective
motor has been triggered.
Rectify cause for over-loading. Customer Service
Error code 26 is displayed Overflow protection switch of the
advance pressure pump has been
triggered.
Rectify cause for over-loading. Customer Service
Error code 40 is displayed The water shortage safeguard in
the swimmer tank has got activat-
ed.
Remove the water shortage. Operator
Swimmer valve is jammed. Check swimmer valve for free movement. Operator
Error code 41 is displayed The temperature sensor in the
swimmer tank has been activated.
Reduce water infeed temperature. Operator
Error code 42 is displayed Leakage in the high-pressure pipe-
line system.
Locate and seal leakage. Operator
Too many consumer loads open at
the same time.
Close some consumer loads. Operator
Pressure sensor for high pressure
defective.
Replace pressure sensor. Customer Service
Error code 43 is displayed Leakage in the high-pressure pipe-
line system.
Locate and seal leakage. Operator
Pressure sensor for high pressure
defective.
Replace pressure sensor. Customer Service
Error code 45 is displayed Pressure too high (> 300 bar). Incorrect nozzle inserted. Insert correct noz-
zle.
Operator
Pressure sensor for high pressure
defective.
Replace pressure sensor or cable. Customer Service
Error code 46 is displayed Flowmeter issues signal > 50 l/min
flow, although no pump is running.
Check flowmeter, replace if required. Customer Service
26 EN
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher HDC 90-10 Advanced wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info