Troubleshooting
DANGER
Risk of injury! The main switch of the vacuum cleaner is to be switched off or the Cekon plug must be unplugged while carrying out
any repairs or maintenance jobs.
Fault Possible cause Remedy of whom
Machine is not running; indi-
cator lamp for operations
stand-by (F) is not glowing
There is no voltage in the machine. Check electrical mains. Electrician
Safety time switch is on. Switch off the appliance switch briefly and
switch it on again.
Operator
Fuse in the control circuit (F3) has
burnt off. Fuse is located in the con-
trol transformer (T2).
Install a new fuse; if it burns out again, then
remove the cause for the over-loading.
Customer Service
Pressure switch HP (High pres-
sure) or LP (Low pressure) is defec-
tive.
Check pressure switch. Customer Service
Timer module (A1) defective. Check connections, replace if required. Customer Service
Exhaust thermostat (B8) tripped. Allow plant to cool down. Unlock the exhaust
thermostat (B8). Eliminate the cause for the
disturbance.
Customer Service
+ Indicator lamp for engine
over-heating (G) is glowing
Thermal sensor (WS) in the engine
or the over-current protection
switch (F1) has got activated.
Rectify cause for over-loading. Customer Service
The water shortage safeguard in
the swimmer tank has got activat-
ed.
Remove the water shortage. Operator
Burner does not ignite or the
flame glows off during opera-
tion
Thermostat (B) has been set at a
very low temperature.
Set the thermostat to a higher level. Operator
Machine switch is not positioned to
burner
Switch on the burner. Operator
The water shortage safeguard in
the safety block has got switched
off.
Ensure adequate water supply. Check ma-
chine for leaks.
Operator
The indicator lamp Burner
failure (E) glows*
Fuel tank empty. Refill fuel. Operator
Fuel filter choked. Clean fuel filter - to do that remove the fuel fil-
ter by turning, clean it and again turn it in.
Operator
Photo-cell flame monitoring device
has been set wrongly or is defec-
tive.
Check the correct positioning of the photo-
cell. **
Operator
No ignition spark exists (can be de-
tected through the sight glass in the
burner lid).
Check electrodes distance between ignition
transformer and ignition cable. Rectify the dis-
tance or replace defective parts. Clean it, if
necessary.
Customer Service
Ignition motor is locked. Removing the blockage. Remove the stopper
(I) on the operating plan and unlock the over-
current protection switch. Insert back the
stopper.
Customer Service
Failure of the fuel pump or the fuel
solenoid valve.
Check parts and replace defective parts. Operator
*
Note: Switch the system off and on to unlock the burner fault.
**
32 EN
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher HDS 12-14-4 ST wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info