Position : When the power tool is connected,
the suction is activated automatically.
Position "0 OFF": The device is switched off.
Note
As long as the device is supplied with power, the device
socket can be used as a power source.
Note
Limited for Switzerland only: The socket outlet shall on-
ly be used during operation in dry condition.
Operation
Note
Pay attention to the latest part numbers when purchas-
ing and installing filter bags and cartridge filters.
Information on accessories and spare parts can be
found at www.kaercher.com.
Dry vacuuming
ATTENTION
Vacuuming cold ashes
Device damage
Only vacuum cold ash with an ash pre-separator.
ATTENTION
Defective or wet foam filter / cartridge filter
Device damage
Before starting up, check the foam filter / cartridge filter
for damage, and replace it if necessary. Only vacuum
with a dry foam filter / cartridge filter.
Depending on the equipment variant, a foam filter or a
cartridge filter is included.
For devices with a foam filter: Always use the filter
bag in addition to the foam filter when dry vacuum-
ing.
For devices with a cartridge filter: Always use the fil-
ter bag in addition to the cartridge filter when vacu-
uming fine dust.
Note
Replace the filter bag in good time, as a filter bag that is
too full could be damaged. The fill degree of the filter
bag depends on the amount of dirt vacuumed. The filter
bag should be replaced more frequently when vacuum-
ing fine dust, sand, etc.
Wet vacuuming
ATTENTION
Wet vacuuming with a filter bag
Device damage
Do not use a filter bag when vacuuming wet.
ATTENTION
Operation with full container
When the container is full, a float switch closes the suc-
tion opening and the device runs at a higher speed.
Switch off the device immediately and empty the con-
tainer.
Note
If the device falls over, the float can also close. To make
the device capable of vacuuming again, set up the de-
vice, switch it off, wait 5 seconds and then switch it on
again.
Working with power tools (only for devices
with a built-in socket)
CAUTION
Unintentional starting of the power tool
Injury or property damage
Make sure that the power tool is ready for operation as
soon as it is connected to the device socket.
1. Connect the suction hose.
Illustration F
2. If necessary, adjust the adapter to the connection di-
ameter of the power tool using a suitable tool.
3. Put the adapter on the handle of the suction hose.
4. Mount the suction hose with the adapter on the pow-
er tool.
Illustration L
5. Plug the mains plug of the power tool into the device
socket.
Illustration M
6. Set the trigger to .
Illustration K
The suction is activated automatically.
Note
Note the maximum connected load (see information on
the device socket).
Note
As soon as the power tool is switched on, the suction
turbine starts up with a 0.5 second delay. If the power
tool is switched off, the suction turbine continues to run
for approx. 5 seconds in order to suck in the residual dirt
in the suction hose.
Blower function
The blower function can be used to clean areas that are
difficult to reach or where vacuuming is not possible,
e.g. leaves in a gravel bed.
Insert the suction hose into the blower connection.
The blower function is now activated.
Illustration N
Interrupting operation
1. Set the trigger to "0 OFF".
The device is switched off.
2. Variant 1: Place the handle of the suction hose in the
intermediate parking position.
Illustration O
Variant 2: Attach the floor nozzle in the parking po-
sition.
Illustration P
Ending operation
1. Set the trigger to "0 OFF".
The device is switched off.
2. Pull out the mains plug.
3. Remove the device head.
Illustration B
4. Empty the container.
Illustration Q
5. Storage possibility:
Illustration T
Note
The suction hose can be wrapped around the device
head and attached to the device head with the help of
the hose collar.
6. Store the device in a dry and frost-proof room.
Care and service
General care instructions
Clean the device and plastic accessory parts with a
commonly available plastic cleaner.
Rinse the container and accessories with water, as
necessary, and dry them before further use.
Clean the foam filter / cartridge filter
1. If necessary, the foam filter / cartridge filter can be
cleaned under running water. To do this, remove the
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher KWD 3 P S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info