804520
15
Zoom out
Zoom in
Vorherige Seite
1/168
Nächste Seite
English 15
Closing the suction connection
1. Fit a plug exactly into the suction connection.
Illustration G
2. Push the plugs in until they engage.
3. Close the suction connection tightly with the plug by
turning it clockwise.
Note
The bayonet connection ensures a precise fit.
Removing the safety filter bag
The safety filter bag must always be removed when
vacuuming wet substances.
1. Unlock and remove the suction head.
2. Fold up the safety filter bag.
Illustration H
3. Take off the protective film and close the ventilation
holes with a self-adhesive tab.
Illustration I
4. Pull the safety filter bag out towards the back.
5. Seal the suction connection opening of the safety fil-
ter bag tightly with a sealing cap.
Illustration J
6. Close the safety filter bag tightly with the attached
cable tie.
Illustration K
7. Remove the safety filter bag.
8. Clean the container inside with a moist cloth.
9. Dispose of used safety filter bag in dust-tight bag in
accordance with statutory regulations.
10. Fit and lock the suction head.
General
We recommend switching off the "Automatic filter
dedusting" function when vacuuming wet dirt with
the crevice nozzle or the upholstery nozzle (option-
al), or when sucking mainly water out of a container.
The device switches off automatically when the
maximum fluid level is reached.
When vacuuming non-conductive liquids (e.g. drill
emulsion, oils and grease) the device does not au-
tomatically switch off when the container is full. The
filling level must be continuously monitored and the
container emptied on a timely basis.
On completion of wet vacuum cleaning: Clean the
flat fold filter using the dedusting function. Clean the
electrodes with a brush. Clean the container with a
moist cloth and dry it off.
Clip connection
The suction hose is equipped with a clip system. All ac-
cessory parts with a nominal width of 35 mm can be
connected.
Illustration L
Operation
Turn switch
Switching on the device
1. Connect the mains plug.
2. Switch on the device at the turn switch.
Adjusting the suction power
1. Adjust the suction power (min-max) via the rotary
control.
Working with power tools
DANGER
Danger of electric shock
Risk of injury and damage.
The socket is only intended for direct connection of pow-
er tools to the vacuum cleaner. Any other use of the
socket is prohibited.
1. Plug the mains plug of the power tool into the power
socket on the vacuum cleaner.
2. Switch on the device at the turn switch. Control lamp
lights up, vacuum cleaner is in standby mode.
Note
The vacuum cleaner is automatically switched on and
off with the power tool.
Note
The vacuum cleaner has a startup delay of up to 0.5
seconds and an after-running time of up to 15 seconds.
Note
See the Technical data for the permissible power rating
of the power tool.
3. Adapt the tool adapter to the connection of the pow-
er tool.
Illustration M
4. Remove the angle piece from the suction hose.
Illustration N
5. Install the tool adapter on the suction hose.
6. Connect the tool adapter to the power tool.
Illustration O
7. Set the minimum volume flow on the turn switch for
suction hose cross section. The scale shows the
suction hose suction hose cross section.
Note
The different suction hose cross sections are necessary
in order to adapt to the different connection cross sec-
tions of the processing machines.
Note
For operation as a dust removal device for mobile oper-
ation (processing machine plugged into the vacuum
cleaner) the integrated monitoring system must be ad-
justed to suit the connected processing machine (dust
generator). This means that the user must be warned
when the flow rate drops below the minimum value 20
m/s needed for correct vacuuming.
Note
Information on the minimum flow rate depending on the
vacuum can be found on the type plate.
Automatic filter dedusting
The device is equipped with a special filter dedusting
function, which is particularly effective against fine dust.
The flat fold filter is automatically cleaned every 15 sec-
onds by a blast of air (pulsing noise).
Switching off the device
1. Switch off the device at the turn switch.
2. Pull out the mains plug.
Device ON
Automatic filter dedusting: OFF
Device OFF
Device ON
Automatic filter dedusting: ON
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher NT 75-1 Tact Me Te H wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info