657211
14
Zoom out
Zoom in
Vorherige Seite
1/174
Nächste Seite
– 8
The power nozzle can be installed onto the detail nozzle
as an accessory.
The power nozzle increases the emission speed of the
steam. Therefore, it is well-suited for cleaning very
tough dirt, blowing out corners, grooves, etc.
Illustration
Attach the power nozzle to the detail nozzle ac-
cording to the round brush.
The round brush can be installed onto the detail nozzle
as an accessory. This round brush allows to clean large
rounded surfaces (e.g. sink, shower tray, bathtub, kitch-
en sink).
ATTENTION
Not suitable for cleaning sensitive surfaces.
Illustration
Attach the round brush to the detail nozzle.
Pull the cloth cover over the hand nozzle. Especially
well-suited for small washable areas, shower stalls and
mirrors.
Illustration
Install hand nozzle on steam gun.
Suited for all washable walls and floor coverings, e.g.
stone floors, tiles and PVC floors. Work slowly on very
dirty surfaces to allow the steam to act on the dirt for a
longer period of time.
Note
Detergent residue or care emulsions that are still pre-
sent on the surface to be cleaned can lead to streaks
during steam cleaning. However, these will disappear
with repeated cleaning procedures.
Illustration
Connect the extension tubes with the steam gun.
Connect the floor nozzle to the extension tubes.
Illustration
Attach the floor cloth to the floor nozzle.
Tip extension tube far forward until it is perpendic-
ular, thereby the side flaps of the floor nozzle fold
up down.
Place the floor nozzle on top of the floor cloth, allow
the side flaps to slide into the two tabs of the floor
cloth.
Tip the extension tube back again, thereby the side
flaps lock and the cloth firmly at the floor nozzle.
Illustration
During work breaks, hook the floor nozzle into the
parking holder.
Rinse the steam cleaner boiler at the latest after 10 boil-
er fillings.
Disconnect the mains plug from the socket.
Allow the steam cleaner to cool down.
Empty the water reservoir.
Remove the accessories from the accessory com-
partments.
Illustration
Open the maintenance lock. For this, place the
open end of an extension pipe onto the mainte-
nance lock, lock it into the guide and unscrew it.
Fill the boiler with water and swing it strongly. This
dissolves lime scaling residing on the boiler bottom.
Illustration
Completely empty the steam boiler to remove exist-
ing water.
As limes cale builds up on the boiler walls, we recom-
mend to de scale the boiler in the following intervals (RF
= reservoir fillings):
Note
The hardness of the tap water can be inquired at your
water management office or the municipal utilities.
Disconnect the mains plug from the socket.
Allow the steam cleaner to cool down.
Empty the water reservoir.
Remove the accessories from the accessory com-
partments.
Illustration
Open the maintenance lock. For this, place the
open end of an extension pipe onto the mainte-
nance lock, lock it into the guide and unscrew it.
Illustration
Completely empty the steam boiler to remove exist-
ing water.
Use KÄRCHER descaler sticks for descaling.
Please follow the dosing instructions on the pack-
aging when preparing the descaler.
Pour the descaling solution into the boiler and allow
it to react for approximately 8 hours.
Completely empty the descaling solution after 8
hours. A small amount of the solution will remain in
the boiler. Therefore, you should rinse the boiler
two to three times with cold water to remove any
residues of the descaler.
Illustration
Completely empty the steam boiler to remove exist-
ing water.
Allow the storage compartment for the mains cable
to dry.
Screw the maintenance lock in using the extension
pipe.
Fill the water reservoir
The steam cleaner is ready to use.
Note
The floor cleaning cloth and the cloth cover have been
pre-washed and can be used immediately for working
with the steam cleaner.
You can wash dirty floorcloths and cloth covers in
the washing machine at 60°C. Do not use a liquid
softener as this would affect the ability of the cloths
to pick up dirt. You may tumble dry the terry cloths.
The microfiber cloths are not suitable for the tum-
ble.
Power nozzle
Round brush (big)
Hand nozzle
Floor nozzle
Parking the floor nozzle
Care and maintenance
Rinsing the steam boiler
Descaling the Steam Boiler
Degree of hardness ° dH mmol/l TF
I soft 0-7 0-1,3 100
II medium 7-14 1,3-2,5 90
III hard 14-21 2,5-3,8 75
IV very hard >21 >3,8 50
Care of the Accessories
14 EN
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher SC 4 Premium wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info