Care and maintenance
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
DANGER
Danger from hot water, steam and hot surfaces
Risk of scalding and burns
Allow the device to cool down prior to all work on the de-
vice.
Rinsing the boiler
Rinse the steam cleaner boiler at the latest after every
5th filling of the boiler.
1. Fill the steam boiler with water and shake it vigor-
ously. Lime residue which has been deposited on
the bottom of the steam boiler will be released as a
result.
2. Pour out the water.
Illustration C
Descaling the boiler
In order to remove lime adhering to the boiler wall, we
recommend cleaning the boiler with the KÄRCHER Bio
Descaler RM 511. The KÄRCHER Bio Descaler RM 511
is a citric acid-based product that is completely biode-
gradable.
ATTENTION
Danger from unsuitable descaler
Risk of damage
Only use descalers that have been approved by
KÄRCHER in order to prevent damage to the device. Do
not use vinegar or similar agents.
ATTENTION
Danger from descaling solution
Risk of damage
Never fill the descaling solution into the fresh water
tank, as this will damage the pump.
1. Pull the mains plug out of the socket.
2. Drain the water completely out of the steam boiler.
3. Completely dissolve a two bags of descaler in 2 li-
tres of warm water, stirring constantly.
4. Pour the descaling solution into the kettle. Do not
screw the safety lock onto the device during the des-
caling process.
DANGER
Danger from inhalation of aerosols
Health risk
Do not use the device while descaler is still present in
the boiler.
5. Allow the descaler solution to take effect for approx.
8 hours.
6. Pour out the descaling solution. Rinse the boiler at
least two more times with cold water to ensure that
there are no more residues in the device.
7. Switch on the device.
8. Press the reset button until the "Descaling" indicator
light goes out. The device is now ready for use.
Note
After approx. 50 hours of operation, the "Descaling" in-
dicator light indicates the next required descaling.
Replacing the filter
The filter may clog if contaminated water is used. This
becomes evident through exceptionally long running
times of the pump or complete functional failure.
1. Change the filter.
Illustration D
Troubleshooting guide
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
DANGER
Danger from hot water, steam and hot surfaces
Risk of scalding and burns
Allow the device to cool down prior to all work on the de-
vice.
DANGER
Danger from improper repair work
Risk of injury and damage
ave repair work carried out by the authorised customer
service only.
The "Fresh water tank water shortage" indicator
light lights up red
1. Refill water.
The "Descaling" indicator light lights up white
1. Descale the device.
Customer Service department
If the malfunction cannot be corrected, the device must
be checked by the Customer Service department.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Accessories and spare parts
Only use original accessories and original spare parts.
They ensure that the appliance will run fault-free and
safely.
Information on accessories and spare parts can be
found at www.kaercher.com.
Special accessories
Only special accessories approved by the manufacturer
may be used.
Description Order number
Bio descaler RM 511 (3x 100 g pow-
der)
6.295-987.0
Caddy trolley 6.962-239.0
Bristle crown set with brass bristles 2.863-075.0
Bristle crown set 2.863-077.0
Microfibre cloth 6.905-921.0
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher SG 4-4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info