– 2
NOTICE
The shorter the hose length and the larger the hose di-
ameter, the higher the pump capacity.
To prevent clogging of the pump, use a prefilter with
hose diameters of less than 1¼ “.
SP 5 Dirt, special accessories
SP 7 Dirt, integrated in the base
The pump connection is equipped with a plug system
(Quick-Connect).
The unmounted connection nozzle (SP 5 Dirt) or the
connection nozzle with pump connecting piece (SP 7
Dirt) is enclosed in the device.
Illustration
To remove the connection nozzle, press the Quick-
Connect (grey button).
Illustration
(SP 5 Dirt)
Slide the hose clamp onto the hose.
If a ¾“ or 1“ hose is used:
Screw pump connecting piece (see special acces-
sory) onto the connection nozzle.
Slide the hose onto the pump connecting piece and
secure it by means of a hose clamp.
Slide the connection nozzle into the Quick-Connect.
NOTICE
To increase the flow volume, the pump connecting
piece can be shortened according to the hose used.
If a 1¼ “ hose is used:
Slide the hose onto the connection nozzle and se-
cure by means of a hose clamp.
Slide the connection nozzle into the Quick-Connect.
Illustration
(SP 7 Dirt)
Screw the pump connecting piece onto the connec-
tion nozzle.
Slide the hose clamp onto the hose.
Slide the hose onto the pump connecting piece and
secure it by means of a hose clamp.
Slide the connection nozzle into the Quick-Connect.
NOTICE
Hoses with a diameter of 1“, 1¼“ and 1½“ can be con-
nected to the pump connecting piece.
To increase the flow volume, the pump connecting
piece can be shortened according to the hose used.
Illustration
Snap the float switch into the height adjustment.
Safely place the pump on a stable surface in the
feed fluid or immerse it using a rope tied to the car-
rying handle.
NOTICE
The suction area must not be blocked by soiling.
In case of muddy ground, place the pump on a brick or
the like.
Ensure that the pump is level.
Do not carry the pump on the cable or the hose.
DANGER
Risk of mortal danger on account of electric shock!
Do not touch feed fluids, the rope attached to the carry-
ing handle as well as objects that are in contact with the
feed fluid (e.g. pipelines extending into the water, rail-
ings, etc.).
Illustration
With a low fluid level, possibly drawn air or air that is
present in the pump escapes via the automatic venting
device. In addition, fluid may leak at this spot.
If the pump has suction problems with a low fluid level,
unplug and plug in the mains plug repeatedly in order to
support the suction process.
Illustration
Adjust the float switch via the height adjustment
and the cable length between float switch and
height adjustment.
NOTICE
In the automatic mode, the float switch controls the
pumping operations automatically .
The pump switches on as soon as the float switch has
reached the switch-on height due to the rising fluid level.
The pump switches off as soon as the float switch has
reached the switch-off height due to the falling fluid level.
Ensure that the float switch is not obstructed in any way.
The cable between the float switch and the lock must be
at least 2.5 cm long.
Switch-on height / switch-off height (float switch in
the lowest position):
Switch-on height / switch-off height (float switch in
the upmost position):
*The switching height can vary depending on the posi-
tion of the float switch.
Likewise, the cable length between the float switch and
the lock can influence the switching heights. We recom-
mend retaining the preset cable length.
Insert the mains plug into the socket.
Illustration
Secure the nose on the float switch into the open-
ing of the lock pointing up.
NOTICE
In manual operation the pump remains switched on
continuously.
In order that the pump draws independently in manual
operation, the fluid level must be at least 60 mm (SP 5
Dirt) or 50 mm (SP 7 Dirt).
The pump can pump up to a residual fluid height of
25 mm (SP 5 Dirt) or 35 mm (SP 7 Dirt).
The stated residual fluid height is only achieved in man-
ual operation.
Insert the mains plug into the socket.
ATTENTION
Risk of damage! Dry running leads to increased wear;
never leave the pump unattended during manual oper-
ation. Switch off immediately in case of dry running.
Start up
Operation
Automatic venting device
Automatic operation
Min / Max SP 5 Dirt SP 7 Dirt
Switch-on height
cm*
18 / 21 cm 20 / 24 cm
Switch-off height
cm*
4 / 12 cm 6 / 15 cm
Min / Max SP 5 Dirt SP 7 Dirt
Switch-on height
cm*
28 / 31 cm 33 / 36 cm
Switch-off height
cm*
14 / 22 cm 19 / 27 cm
Manual operation
11EN
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher SP 5 Dirt wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info