– 6
Level 4: High suction range
For vacuuming durable floor coverings, hard floors,
high-pile carpets and heavily soiled surfaces.
Important notice! The device will shut down automati-
cally if there is risk of overheating. Turn the device off
and pull out the mains plug. Make sure, that the nozzle
and suction pipe are not clogged, and that the filter does
not need changing. After eliminating the fault, allow the
device to cool down for a at least 1 hour; then the device
will be ready for operation again.
Illustration
Illustration
Upholstery nozzle: for cleaning upholstered furni-
ture, mattresses, laced curtains, etc.
Crevice nozzle: for edges, joints and heaters
Furniture brush: for gentle cleaning of furniture
and delicate objects, such as books, etc.
Illustration
Illustration
Roll-up the cable.
Engage the device (telescopic pipe is not extend-
ed) in parking position on the floor nozzle.
The device can also be stored in a horizontal posi-
tion, for example on a shelf on in a cupboard.
Note
Store the appliance in a dry room.
Recommendation: Empty main filter after every use.
For rest of procedure see:
Figure to
Note
When you unscrew it, the filter is automatically
cleaned and the dirt is removed.
Recommendation: Remove long life filter at the latest
every 3 months, empty them and clean them if neces-
sary.
ATTENTION
The amount that can be vacuumed up can vary depend-
ing on the vacuuming material.
For fine dust, in particular, emptying may be necessary
earlier.
In order to ensure good filtration, replace long life filter
with new filter every 2 years.
For rest of procedure see:
Figure to
Notes
When you unscrew it, the filter is automatically
cleaned and the dirt is removed.
Reinsert the long life filter in the filter box according
to the marking and screw it in completely until the
red safety rod is no longer visible.
ATTENTION
If the red safety rod is still visible, the filter box can-
not be inserted into the device.
The filter lock must therefore be screwed in all the
way.
Only install dry long life filters in the device.
Recommendation: In order to ensure good filtration,
replace the exhaust filter once a year.
Illustration
Remove the exhaust filter cover upwards at an an-
gle along the edge of the device.
Press the exhaust filter together on both sides and
remove.
Attach a new exhaust filter and lock in place.
Place the exhaust filter cover on the edge of the ap-
pliance, push it downwards and lock in place.
Reduced suction performance can be caused by:
Blockage in accessories: Remove the blockage
carefully with a narrow tool.
Illustration
Blockage in telescopic suction pipe: Lever the cov-
er on the handle off with a screwdriver and then re-
move the blockage carefully with a narrow tool.
Check to see whether the filters are intact or dam-
aged.
See chapter "Care and Maintenance".
Subject to technical modifications!
Adjusting the floor nozzle
Hard surfaces Carpets / carpeted
floors
Using accessories
Finish operation
Transport, storage
Care and maintenance
Emptying the main filter
Emptying long life filter
Replacing exhaust filter
Troubleshooting
Technical specifications
Voltage 220 - 240 V
Current type 50-60 Hz
Mains fuse (slow-blow) 10 A
Protective class II
Weight (without accessories)
Device with floor nozzle 3,2 kg
Action radius
VC 5 8,5 m
VC 5 Premium 10,0 m
Dimensions
(Device in parking position) ø 182 x
261 x 621 mm
Nominal width, accessories 35 mm
Eco design as per 666/2013
Energy efficiency category A
Indicative annual energy con-
sumption 20 kWh/a
Carpet cleaning class C
Hard floor cleaning class A
Dust emission class A
Sound power level LWA 77 dB(A)
Rated power input 500 W