936.2121/D/0206/2.4e
General
Only the power supply unit NCF 18, order no. 230636, guarantees that the EMC requirements are met.
Unoccupied subscriber outputs must be terminated with 75 Ω terminating resistor EMK 03, order no. 273169.
Max. ambient temperature: -20 to +55 °C.
RF and DC connections: F-connectors.
Accessories (in the scope of delivery):
EXR 554: 5-way connection element
EXR 558: 5-way connection element
VWS 551: 5-way connection element
Settings of the satellite receivers
For optimal control of the switching matrices in the 500 series, you can carry out the following
settings in the menu setting of your satellite receiver*).
Setting Result
DiSEqC off Switch-over time of the receiver is reduced
22 kHz ––> High/Low For control of one satellite analogue and digital
22 kHz ––> Pos. A/B For conrol of two satellites (multifeed)
LNB-power supply in standby mode ”Off” Power saving
*) Terms from the setting menus of satellite receivers from other manufacturers may differ.
The distribution amplifier VWS 551 and the feed systems are always supplied with power from the end-line switching
matrix (e.g. EXR 508, order no. 20510002). The VWS 551 can also be mains fed using a power supply unit NCF 18,
order no. 230636.
Feature VWS 551
The VWS 551 can be configurated with a 75 Ω terminating resistor EMK 03.
With this configuration, a higher amplification is activated and the level adjuster is switched on.
An additional compensation of cable loss is possible (cable mode).
Attention
Screw on EMK 03!
Clip-on mounting set ZAH 05 Clamping rail
e. g. 20 m LCD 90