5 - POSITIONING
The installation has been implemented by qualified technical
personnel only and that the instructions contained in the
present manual and the local regulations in force have been
adhered to.
Choose the installation place according to the following
criteria:
 customer approval
 Internal
 in a dry room/compartment where the temperature cannot
fall below 0 degrees
 guarantee good unit operation
 safe accessible position
 enough space for installation and maintenance shall be
preserved.
 the air inlet and outlet should be free from obstacles and
strong wind.
 the base surface should be flat, surface should be inclined
no more than 2°and able to bear the weight of the unit and
suitable for installing the unit without increasing noise or
vibration.
 the operation noise and air flow expelled shall not affect
neighbors.
 If the unit has to be installed on a metal part of building,
make sure the well electric insulation which should meet
the relevant local electric standard.
 use of air from heated rooms could penalise the heating
performance of the building
 the unit must be securely fixed, elsewise, noise and
shaking may be resulted.
 make sure that there’s no obstacle around the unit.
The external air temperature must also be considered when
installing this unit, in heat pump mode the external air
temperature must be above -7°C and below 43°C. If the
externalair temperature falls outside these upper and lower
limits, the electrical elements will activated to meet the hot
water demand and the heat pump does not operate.
The unit should be located in an area not subject to freezing
temperatures. The unit located in unconditioned spaces(i.e.,
garages, basements, etc.) may require the water piping,
condensate piping, and drain piping to be insulated to shelter
against freezing.
Installing the unit in any of the following places may lead to
malfunction:
 The site contains mineral oils such as cutting lubricant
 Seaside where the air contains much salt.
 Hot spring area where corrosive gases exist, e.g., sulfide
gas.
 Factories where the power voltage fluctuates seriously.
 The place with direct sunlight and other heat supplies. If
there’s no way to avoid these, please install a covering.
 Place like kitchen where oil permeates.
 Place where strong electromagnetic waves exist.
 Place where flammable gases or materials exist.
 Place where acid or alkali gases evaporate.
5.1 - INSTALLATION REQUIREMENTS 5.2 - CONSIDER SOUND EMISSIONS
Noise levels could represent an inconvenience if installed in
areas that require extreme silence, example near bedrooms.
Unit dimension / Functional spaces
Unit 190
190S (with solar)
300
300S (with solar)
Width A 560 650
Height B1830 1930
Diameter C 560 650
Functional
spaces
D = 600 = 600
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun COMPAK KHPA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info