NO.
Icon
Description
20
Frequency unit icon
It will be constantly light when the control panel displays frequency of the compressor.
21
ON/OFF and OK button
1.Press ” to confirm the former operation when finishing the setting work.
2.Long press ” for 3S will recovers to factory default mode.
22
Mode choice function/Function choice/Back function button
1.Mode choice function. Choose operation mode.
2. Function choice. Long press it for 3s to enter function setting in the main interface.(Clock setting, Timing on and timing off
setting)
3. Back to the previous menu. Long press it for 3s to back to previous menu in the function setting interface. Top menu is the
main interface.
23
Up
1.(Value increase)
2.Forward to the previous interface.
24
Down
1.(Value decrease)
2.Backward to the next interface.
7.2.2 Control panel operation description
1. ON/OFF
The first time to powered on the unit,
Operation panel displays “OFF”. Long press for 3s,
to unlock “OFF” status and enter into standby status.
Power on: In the standby status, press ” to enter mode
choice function. Press “ ” circularly to choose one kind
of “power on” mode, the mode icon will flicker at the moment.
Press “ to confirm the power on mode. The unit will run
as the chosen mode when the mode icon will be constantly light.
Power off: Press ” in the main interface to enter mode
choice function and the icon which indicate the current mode will
flicker. Press circularly to choose power off mode,
” will flicker at this moment. Press ” button to
and go to the next step.
By this time, the last 2 digits of the nixie tube will flicker and
press ” or “ ” to adjust temperature and set the
temperature of the inlet water. Press ” to confirm and
move to the next step.
By this time, the first 2 digits of the nixie tube will flicker and
press or “ to adjust time of timing on. Press
to confirm and switch to minute setting automatically. The last 2
digits of the nixie tube will flicker and press or “ ” to
adjust minute setting of timing on.(minimal unit of minute
adjustment: 15 minutes) .
Press “ ” to confirm. The first group setting is finished and
” will be constantly light. When processing the second
timing setting, repeat the 1-2 operation above. When the nixie
confirm the power off mode. By this time,
light and the unit stops.
2. Mode choice and temperature settings
will be constantly tube displays “01” and flicker, press “ or ” to choose
the timing on group. When the nixie tube displays “ 02 ” which
means setting timing on function of the second group.
Refers the timing on setting operation of group 1 to set that of
group 2.
Press “ ” in the main interface to enter mode choice
function. The “Mode” icon will flicker. Click ” circularly to
choose a mode. The circulating order is “Cooling mode”→
“Heating mode”→“Water pump mode” →“Power off mode”
“Cooling mode”. The chosen mode will flicker.
Press “ ”or ”to increase/decrease the temperature in
the chosen mode.
Press “ ” to confirm power off mode and the set
temperature. Mode icon will be constantly light and the unit will
run as the chosen mode.
Press “ or in the main interface to increase/decrease
the temperature in the chosen mode.
3. Clock setting
Long press ” for 3s to enter function interface.
clock icon will flicker. Press ” to enter clock setting
function. “ ” icon will be constantly light and the first 2 digits
on nixie tube will flicker. Press or ” to set minute.
Press “ ” when finish setting and ” will be
extinguished.
4. Timing setting 1
Timing on setting
Long press ” for 3s to enter function interface.
clock icon will flicker. Press ” again to enter timing on
function. “ ” will flicker and press ” to enter timing
on setting.
At this moment, last 2 digits of the nixie tube display “01” which
means the first group setting begins. Press ” to the next
step.
By this time, mode icon will flicker and press ” to
choose timing on mode. Press ” to confirm your choice
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun KEM-05 DVN1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kaysun KEM-05 DVN1

Kaysun KEM-05 DVN1 Bedienungsanleitung - Holländisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info