771460
5
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
I&O manual
3
2.1.3 Versions with casing
Supply voltage 220-240V~ 1ph 50Hz;
Finned coil type heat-exchanger consisting of copper tubes and
aluminum fins, with connections on the left reversible to fit on
the right.
Three-speed centrifugal blower with aluminum blades statically
and dynamically balanced. Directly-coupled motor equipped
with internal thermal protection and condenser permanently in
circuit.
Casing in pre-painted galvanized steel sheet, clad in a protective
film of PVC complete with thermoacoustic insulation, grilles in
heat-resistant ABS polymer with fixed vanes.
Condensation collection tray with natural drainage, complete
with anti-condensation insulation.
Mesh filter in regenerable polypropylene.
2.1.5 Restrictions on use
CAUTION
IMPORTANT!
The machine has been designed and built solely and
exclusively to function as a ceiling-mounted air-handling
terminal, supplied through ducting or paneling; any other use
is expressly prohibited.
Installation of the machine in an explosive environment is
also forbidden.
2.1.6 Operation range
Use the system in the following temperature for safe and
effective operation.
Temperature Room
water inlet
Mode
Cooling operation
Heating operating
(cooling only type
without)
temperature
17°C32°C
0°C30°C
temperature
3°C20°C
30°C65°C
NOTE
1 If air conditioner is used outside the above conditions, it
may cause the unit to function abnormally.
2.1.4 Built-in version II
VERSION I
Fig.2-2
2 The phenomenon is normal that the surface of air
conditioning may condense water when the relative larger
humidity in room, please close the door and window.
3 Optimum performance will be achieved within these
Supply voltage 220-240V~ 1ph 50Hz;
Finned coil type heat-exchanger consisting of copper tubes and
aluminum fins, with connections on the left reversible to fit on
the right.
Three-speed centrifugal blower with aluminum blades statically
and dynamically balanced.
Directly-coupled motor equipped with internal thermal protection
and condenser permanently in circuit.
Structure in galvanized sheet steel.
Condensation collection tray with natural drainage, complete
with anti-condensation insulation.
Mesh filter in regenerable polypropylene.
operating temperature range.
4 Water system operating pressure: Max: 1.6MPa, Min:
0.15MPa.
2.1.7 Information about further risks and unavoidable hazards
CAUTION
IMPORTANT!
Pay the utmost attention to the signs and symbols located on
the appliance.
If any risks remain is spite of the provisions adopted, or if
there are any potential or hidden risks, there are indicated by
adhesive labels attached to the machine.
CAUTION
IMPORTANT!
Only use original spare parts and accessories. The company
shall not be held liable for damage caused by tampering or
work carried out by unauthorized personnel or malfunctions
caused by the use of non-original spare parts or accessories.
IMPORTANT!
In the case of a water supply with a particularly high content
of hard water salts, it is advisable to fit a water softener.
VERSION II
Fig.2-3
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun KFC-SE-2T-900D wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info