771555
34
Zoom out
Zoom in
Vorherige Seite
1/38
Nächste Seite
32
NOTE
Before repair and maintenance, ensure that the hydro module is powered off.
8 MAINTENANCE
● Water pressure
Check if the water pressure is above 0.3 bar. Add water if necessary.
● Water lter
Clean the water lter. ● Water pressure relief valve
Check for correct operation of the pressure relief valve by turning the red knob along the valve counter-clockwise:
1. If you do not hear a clacking sound, contact your local dealer.
2. If water keeps running out of the unit, close both the water inlet and outlet shut-off valves rst and then contact your local
dealer.
● Pressure relief valve hose
Check that the pressure relief valve hose is positioned appropriately to drain the water. If the drain pan kit is installed, make
sure that the pressure relief valve hose end is positioned in the drain pan.
Auxiliary heater vessel insulation cover
Check that the auxiliary heater insulation cover is fastened tightly around the auxiliary heater vessel.
● Sanitary hot water tank pressure relief valve (eld supply)
Applies only to installations with a sanitary hot water tank. Check for correct operation of the pressure relief valve on the
sanitary hot water tank.
● Sanitary hot water electric heater
Applies only to installations with a sanitary hot water tank. It is advisable to remove lime buildup on the electric heater to
extend
its life span, especially in regions with hot water. To do so, drain the sanitary hot water tank, remove the electric heater from
the sanitary hot water tank and immerse in a bucket (or similar) with lime-removing product for 24 hours.
● Indoor unit control box
1. Carry out a through visual inspection of the control box and look for obvious defects such as loose connections or defective
wiring.
2. Check for correct operation of contactors by the use of an ohmmeter. All of these contactors must be in open position.
Important information for the used refrigerant
This product has the uorinated gas, it is forbidden to release to air.
Refrigerant type: R410A/ Kg or R134a / Kg
Volume of GWP: 2088 or 1430; tonnes CO2 equivalent
GWP=Global Warming Potential
ATTENTION:
Frequency of Refrigerant Leak Checks
1) For equipment that contains uorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent or more,but of less
than 50 tonnes of CO2 equipment,at least every 12 months , or where a leakage detection system is installed, at least every
24 months.
2) For equipment that contains uorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more,but of less
than 500 tonnes of CO2 equipment,at least every six months , or where a leakage detection system is installed, at least every
12 months.
3) For equipment that contains uorinated greenhouse gases in quantities of 500 tonnes of CO2 equivalent or more,at least
every three months ,or where a leakage detection system is installed, at least every six months.
4) This air-conditioning unit is a hermetically sealed equipment that contains uorinated greenhouse gases.
5) Only certicated person is allowed to do installation, operation and maintenance.
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun KWF-140 HT ACS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kaysun KWF-140 HT ACS

Kaysun KWF-140 HT ACS Bedienungsanleitung - Deutsch - 38 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info