2-8 2001-900-01 Rev. K / August 2010
The measure count (number of readings to take) is set to a
finite value (1 to 99,999) or to infinity. The factory default
value is infinity.
In factory default conditions, the arm layer and scan layer are
transparent to the measurement operation.
2.4 Initial configuration
WAR NI NG
Before turning on the Model 2001, make
sure it is connected to a grounded power
receptacle using the supplied power cord
or the equivalent. Failure to properly
ground the unit creates a shock hazard that
could result in injury or death.
The Model 2001 can save from one to ten user setups in
memory, depending on the installed memory option. You can
select one of the user setups as the power-on default, or have
the instrument power up to either of the two factory defaults
(optimized for “BENCH” or “GPIB” operation). Since the
examples in paragraph 2.5 assume BENCH defaults, reset
the instrument to those settings by performing the following
steps:
1. Press the MENU key to display the MAIN MENU
options as shown below:
MAIN MENU
SAVESETUP GPIB CALIBRATION
TEST LIMITS STATUS-MSG GENERAL
When the lower display line is longer than one line, the
right-most character will be a symbol. Repeatedly
press the key to view the second half of the lower
line, and press the key to return to the first half
display.
Additional information is available for
most front panel operations. Simply press
the INFO key to toggle an INFO display.
Use the and keys to see the
complete lower line.
2. If the SAVESETUP option is not blinking, press the
key until it is and then press ENTER to view the setup
menu:
SETUP MENU
SAVE RESTORE POWERON RESET
3. Press the key until the RESET option of the SETUP
MENU is blinking and then press ENTER to view the
reset menu:
RESET ORIGINAL DFLTS
BENCH GPIB
4. Select the BENCH option by making it blink and
pressing ENTER. The following confirmation message
is displayed:
RESETTING INSTRUMENT
ENTER to confirm; EXIT to abort
5. Press ENTER to confirm. The parameters accessed by
the front panel are now reset to factory defaults for
bench operation. The display will show DC voltage
readings with autorange enabled. The default settings
for DC voltage are:
•Measurement speed (integration time) Normal, 1
power line cycle.
•Digital filter Advanced, 10 readings, 1% noise
tolerance, moving average, enabled.
•Display resolution 6.5 digits.
2.5 Front panel operation
Basic front panel operation will be demonstrated by
examples of measuring DC voltages. The first example
shows readings at default settings and high accuracy
readings. The second example shows storing high speed
readings. These examples are only intended to teach basic
operation.
Details for using the full capabilities of the Model 2001 from
the front panel are contained in Section 3 of this manual. The
manual for the Model 2001-SCAN Scanner Card has
examples for closing and opening channels and scanning
lists of channels.
The front panel operation examples
assume that the Model 2001 is initially set
up for proper operation as explained in
paragraph 2.4.
2.5.1 Measuring DC voltage example
Before starting this example, the front panel display should
show triggered DC voltage measurements. If it does not,
perform a bench reset following the procedure of paragraph
2.4.
Perform the following steps to make DC voltage
measurements with the Model 2001 Multimeter.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Keithley 2001 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info