A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
6.2.7 WeldingMemoryChannel
This 8-bit function represents the currently active memory
channel.
The minimum value is 0.
The maximum value is 199.
The minimum step is 1.
6.2.8 TAST
This 16-bit function value represents the deviation of the
welding head from the groove during TAST (through-arc
seam tracking) operation. A lower value indicates greater
distance from the groove. The value is equivalent to the
welding current and is valid for all processes.
The minimum value is 0.
The maximum (theoretical) value is 6500.
The minimum step is 1.
6.2.9 WeldingProcess
This 8-bit function value represents the current welding
process in use. The value is an enumeration and can be
one of the following values:
0 = Unknown process
1 = MIG
2 = 1-MIG
3 = Pulse MIG
4 = Double pulse MIG
11 = WiseRoot+
14 = WiseThin+
6.2.10 Ready
This signal function indicates readiness of the welding
system. The main power supply must be turned on, the
system software booted up, and the system bus properly
connected. The system is assumed to be ready when a
power source and a wire feeder are found on the system
bus, there is at least one user interface (excluding the web
user interface ) available, and there are no active errors in
the system. If the user identication system is in use, a user
must be logged in.
0 = Welding system not ready. Check that a user
has logged in, all devices are connected properly
and errors are resolved.
1 = Welding system ready
6.2.11 PowerSourceReady
This signal function indicates the status of the power
source. The power source is ready to start welding when it
is not currently in use, when the robot has not requested
welding start, and when crater ll is not active.
0 = Power source not ready yet for a new arc start
1 = Power source ready
6.2.12 CoolingUnitOk
This signal function indicates the status of the cooling
unit. If there is an error in the cooling unit, the signal status
changes and a cooling unit error will be indicated in the
system.
0 = Cooling unit error
1 = Cooling unit OK
6.2.13 ProgramSaved
Saving the parameters takes a while in the system. This
signal function is cleared at the beginning of the save
process and set after completion. The signal reacts (goes
o) when a save operation lasts longer than 150 ms.
0 = Saving new parameters
1 = Save operation ready
6.2.14 RobotHasControl
This signal function indicates the online control status. The
value is copied from the OnlineControl value set by the
robot.
0 = Robot has released full control to the welding
system
1 = Robot has control over wire feed speed,
voltage, ne tuning, and dynamics values
6.2.15 CycleOn
This signal function indicates the status of the welding
cycle. The welding cycle starts at the beginning of the
pre-gas phase and ends at the end of the post-gas phase.
The signal indicates to the robot when it is safe to move
to the next position. However, the welding cycle does not
prevent starting of a new weld – a weld can be started
during the post-gas time.
0 = Welding cycle not active
1 = Welding cycle in progress
47

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kemppi A7 MIG Welder 350 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info