REPEATER OPERATION
Note:
Please consult your dealer for programming the repeater. Due
to the frequency stability on the 6.25 kHz bandwidth channel, when
operating the repeater using an optional OCXO unit, allow the unit to
warm up for 24 hours after turning the power on.
After turning on the power, wait for approximately 10 seconds for
the VCXO or 5 minutes for the OCXO (when mounting) to warm up.
During this time, the CH/STATUS Display will blink. The keys will
function when they are pressed.
When power is applied to the unit, the
POWER
indicator lights
green. Turn the
VOLUME
control clockwise until a click sounds,
to unmute the audio. Rotate to adjust the audio. Turn the
VOLUME
control counterclockwise fully to mute the audio.
The
BUSY
indicator lights green while receiving a signal and the
TX
indicator lights red while transmitting.
Rear Panel
q
RX
IN
jack
Connect an RX antenna or a duplexer to this BNC
receptacle.
w
TEST/SPKR jack
Test input/output jack. Connect an external speaker to
this jack.
e
CONTROL I/O jack
Connect a repeater controller or a remote panel to this
DB-25 interface.
r
SYNC 1 / 2 jack
Connect to another repeater to use synchronous frame
signaling for digital trunking.
t
LAN jack
Connect to Ethernet. Use a Category 5e or higher
standard LAN cable shorter than 3 meters. When using
cables other than this, the repeater performance may
become inadequate.
CONTROLS AND FUNCTIONS
Front Panel
q
w r t
y u
io
e
q
w
r t y
u
e
MICROPHONE
VOLUME
COM
OFF/
POWERCTRL OCXO BUSY TX
1 2
MON
TAKE
OVER
RPT
DISABLE
A B C
3 4 5 6 7 8
STATUS
TEST/SPKR
RX TX
CONTROL I/O
SYNC
1 2
LAN REF OUT REF IN
FUSE
15
DC 13.2V
FUSE 15A
y
REF OUT jack
Connect to another repeater within the site to supply a
reference signal.
u
REF IN jack
Connect from another repeater within the site to receive a
reference signal.
i
FUSE
Insert 15 A blade fuse into this fuse holder.
o
DC
13.2V jack
Connect a 13.2 V DC power supply to this jack.
TX
OUT
jack
Connect a TX antenna or a duplexer to this BNC receptacle.
i
o
TRANSCEIVER OPERATION
Receive
Adjust the volume to your desired level. You may need to
readjust the volume if you are having interference while
receiving a message from your dispatcher or another member
in your eet.
The
BUSY
indicator lights green while a signal is being
received.
Transmit
1
Listen to the channel before transmitting, to make sure it
is not being used.
2
Press the microphone
PTT
switch, then speak in your
normal speaking voice.
The
TX
indicator lights red while transmitting.
3
When you nish speaking, release the
PTT
switch.
!0
!
1
!
2
q
Speaker
w
CH/STATUS Display
Two 17-segment digits display the channel number, name,
or status.
e
STATUS
indicator
Indicates the status of the repeater. (NXDN mode)
r
Programmable Function keys
Press these keys to activate their programmable
functions.
t
COM jack
Connect to the PC using a RS-232C standard DB9
(Female) cross cable.
y
VOLUME
control
Turn clockwise until a click sounds, to unmute the audio.
Rotate to adjust the audio. Turn counterclockwise fully to
mute the audio.
u
MICROPHONE
jack
Connect a microphone to this 8-pin modular jack.
i
POWER
indicator
Lights green when power is supplied to the
DC 13.2V
jack. Blinks red when an abnormal voltage is present.
While blinking, the repeater cannot be used.
o
TX
indicator
Lights red while transmitting.
!0
BUSY
indicator
Lights green while a signal is being received.
!1
OCXO
indicator
The OCXO indicator shows the state of the reference
10 MHz oscillator :
Lights Green when using a reference signal from an
optional OCXO unit (KXK-3).
Lights Orange when using a reference signal from another
repeater.
Lights red when no reference signal is available or when
an error occurs.
Does not light when the reference signal is an internal
VCXO signal.
!2
CTRL
indicator
The CTRL indicator shows the control channel status
while using Digital trunking :
Lights Green when the repeater is used as control channel.
Blinks Green when using a non-dedicated control channel.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood NXR-800 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood NXR-800

Kenwood NXR-800 Bedienungsanleitung - Englisch - 8 seiten

Kenwood NXR-800 Bedienungsanleitung - Holländisch - 2 seiten

Kenwood NXR-800 Bedienungsanleitung - Französisch, Spanisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info