Symptom Probable Cause Corrective Action Refer to
The linear amplifier is not functioning. The REMOTE connector is not properly
connected.
Reconnect the connector properly.
16-13
The audio source selected in Data VOX is
different from the audio source input, or the
input level of the input signal is low.
Check the Data VOX settings or check the input
level of the input signal.
Control relay of the linear amplifier is turned off. Configure to a setting suitable for the linear
amplifier, such as “Active High + Relay Control”
for Keying Logic in the Linear Amplifier menu.
16-14
When a linear amplifier is used for full
break-in operation in the CW mode,
the SWR may deteriorate suddenly or
an abnormal ALC voltage may be
applied when the linear amplifier starts
up.
The linear amplifier in use requires some time
to start up (TL-922, etc.).
Operate in the semi break-in mode by
configuring to a setting that includes an
appropriate delay time for the linear amplifier,
such as “Active High + Relay Control” for
Keying Logic in the Linear Amplifier menu.
16-13
AT-300 is not functioning. It is connected to antenna input connector 2
(ANT 2).
Connect it to antenna input connector 1 (ANT
1).
4-12
The fuse inside this transceiver is blown. Check the fuse, address the cause and replace
the blown fuse with a new one.
17-4
Modulation is too shallow. (FM mode) Microphone gain is low. Configure the microphone gain in Advanced
Menu [10].
5-28
When a commercially available power
meter is used, the TX output power
reading for SSB is low compared to
the other modes.
The peak power of SSB is not correctly
measured.
To ensure correct measurement of the peak
power for SSB, the use of devices such as an
oscilloscope which are capable of displaying
instantaneous waveforms is recommended.
Commercially available power meters may not
be able to measure the peak power fully in some
cases. Please use them as reference values.
Transmission is still held after AT
tuning is complete.
TX hold after AT tuning is configured to ON. Configure TX hold after AT tuning to OFF in
Advanced Menu [7].
4-12
VFO scan does not start. Program Scan is selected. Configure all the settings for memory channels
P0 to P9 to OFF in the Program Scan/VFO Scan
configuration mode. Alternatively, press [VFO/
PRG] to select VFO Scan.
10-1
Memory Scan is not functioning. No data is registered in the memory channels. Register data to the memory channels. 9-2
Group Scan is not functioning. No data is registered in the memory channels
within the group.
Register data to the memory channels of the
corresponding group number.
10-3
All the memory channels within the group are
locked out.
Cancel the lockout for the memory channels to
be scanned.
10-4
Memory Scan is only performed on
specific channels.
Group Memory Scan is selected. Reconfigure or cancel the group selection.
10-3
Voice guidance does not start
automatically.
Auto voice guidance is OFF.
Configure auto voice guidance to On in Menu
[1-06].
13-1
Voice guidance is not output
automatically after Full Reset is
performed.
Menu [1-06] is configured to Off.
Turn on the power while pressing [PF A], or
configure Menu [1-06] to On.
13-1
The [POWER] LED is blinking and the
power of this transceiver does not turn
on.
This transceiver is preparing to activate the
program timer operation.
Wait for the program timer operation to start. To
stop the program timer operation, press [ ] for
4 seconds.
14-4
Program timer is not activated. The timer operation is not configured to ON. Check whether the timer operation has been
temporarily turned off (<< >> goes off) by
pressing F [TIMER] after the timer operation is
configured to ON.
14-4
A firmware version confirmation
screen is displayed and this
transceiver does not start up.
The firmware of this transceiver cannot be
detected.
Rewrite the firmware. If the same symptom
persists after rewriting the firmware, please
send an inquiry to KENWOOD service center
together with the number that is displayed at the
bottom right corner of the message.
17-1
Firmware cannot be updated. The name of the zip file is changed. Update the firmware without changing the
name of the zip file. The file name may be
changed if the file is downloaded to the PC
multiple times.
The zip file is uncompressed. Update the firmware without uncompressing
the zip file.
18 TROUBLESHOOTING
18-4
184

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-890S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-890S

Kenwood TS-890S Bedienungsanleitung - Deutsch - 196 seiten

Kenwood TS-890S Bedienungsanleitung - Holländisch - 196 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info