5
Installation requirements
557 mm
total depth
525 mm
between clamp rails
Location Requirements
Protect the dishwasher and water lines leading to
the dishwasher against freezing. Damage caused by
freezing is not covered by the warranty.
If the dishwasher will be left unused for a period of
time, or in a location where it may be subject to
freezing, we recommend having it ‘winterised’ by
PRODUCT DIMENSIONS
our authorised service personnel. Please contact
our Customer Care Centre.
The dishwasher is shipped ready for installation of
a one hole tap unit. If a two, three, or four hole tap
unit is to be installed, the holes must be cut by a
qualified plumber, according to the Tap unit
manufacturer’s specifications.
3-prong ground type power supply cord - 1045 mm.
CABINET REQUIREMENTS
*NOTE: The coutout must be accurately cut to the dimensions shown within
1,6 mm. Dishwasher top flange overlaps the countertop cutout by 11 mm on
front and back edges and 6,4 mm on sides.
• Cabinetry and countertop must be sturdy enough to support loaded
dishwasher and sink (180 kg).
Radius: 57 mm
Radius: 25 mm
the right back corner must be
cut to this radius
Back right corner: If countertop is
more than 19 mm thick, measure
down 19 mm and cut 45° bevel all the
way around radius.
CRITICAL
RADIUS
11 mm min.
flat surface required
537 mm
(see *NOTE)
For base cabinet
installations, min. 914 mm
width required
864 mm
(see *NOTE)
537 mm
(see *NOTE)
It is recommended that sink
water and drain line
connections be located on
this side of cabinet
It is recommended
that dishwasher
water and drain line
connections be
located on this side
of cabinet
635 mm
deep countertop.
Countertop must
be level
Backsplash
531 mm
561 mm
504 mm
to centre of
check valve
254 mm
dishwasher drain
877 mm
total width
275 mm
to centre
of hole
tap unit
500 mm
maximum
opened
lid height
209 mm
height of sink
166 mm
centre
of
sink drain
856 mm
between
clamp rails
357 mm
centre of
tub drain
Factory
istalled
air gaps
GFCI
(TEST button)
32 mm
19 mm
44 mm