12
Control panel lock
This function locks the controls to prevent accidental activation of the hob. To activate the control panel
lock, switch the hob on and press the Timer button for three seconds; an acoustic signal and a luminous
indicator near the padlock symbol signal activation. The control panel is locked except for the switching
off function. To deactivate the control lock, repeat the activation procedure. The luminous dot goes off and
the hob is active again.
The presence of water, liquid spilled from pots or any objects resting on the button below the symbol can
accidentally activate or deactivate the control panel lock.
Timer
The timer can be used to set the cooking time for a maximum of 99 minutes (1 hour and 39
minutes) for all the cooking zones.
Select the cooking zone to be used with the timer, press the timer and a beep signals the function
(see figure). The display shows “00” and the LED indication comes on. The Timer value can be
decreased and increased by keeping the slider function “+” and “-” buttons pressed. When the set
time has elapsed, an acoustic signal sounds and the cooking zone switches off automatically. To
deactivate the timer, keep the Timer button pressed for at least 3 seconds.
To set the timer for another zone, repeat the above steps. The timer display always shows the
timer for the selected zone or the shortest timer.
To modify or deactivate the timer, press the cooking zone selection button for the timer in question.
CONTROL PANEL WARNINGS.
Residual heat indicator.
The hob is fitted with a residual heat indicator for each cooking zone. These indicators alert the
user when cooking zones are still hot.
If the display shows “H”, the cooking zone is still hot. If the residual heat indicator of a given
cooking zone is lit, that zone can be used, for example, to keep a dish warm or to melt butter.
When the cooking zone cools down, the display goes off.
Incorrect or missing pot indicator.
If you are using a pot that is not suitable, not correctly positioned or not of the correct dimensions
for your induction hob, the message “no pot” will appear in the display (see figure at side). If no
pot is detected within 60 seconds, the hob switches off.
Fast boil function (Booster)
This function, only present on some cooking zones, makes it possible to exploit the hob’s maximum power
(for example to bring water to the boil very quickly). To activate the function, press the “+” button until
“P” appears on the display. After 10 minutes’ use of the booster function, the appliance automatically sets
the zone to level 9.
Instructions for use