13.3 Setting the fan speed
Use the SPEED button (c) to select the
fan speed between “HI” and “LOW”.
13.4 Description of the
operating modes
Use the MODE button (d) to select the
mode COOL, DEHUM or FAN:
COOL: Cooling mode
Temperature and fan speed can be set
as required.
FAN: Ventilation mode
Compressor does not run.
Set fan speed as required.
DEHUM: Dehumidification mode
The mobile air conditioner always runs
fully automatically at 2°C below the
current room temperature.
The fan speed is automatically LOW and
cannot be altered.
NOTE
Do not place any objects on the mobile
air conditioner.
14 Cleaning
Clean the mobile air conditioner
according to use and degree of soiling,
but at least every 4 weeks.
Always allow the mobile air conditioner
to cool down completely before
cleaning!
Cleaning the appliance
• Clean the ventilation openings and
the filter at regular intervals
(approx. every 2 weeks) to prevent
the performance of the mobile air
conditioner from deteriorating.
• Wipe down the outside of the mobile
air conditioner with a dry or slightly
damp cloth.
• Then rub the mobile air conditioner
completely dry.
• Remove dust and soiling from the
ventilation openings using a suitable
soft brush.
Cleaning the filter
1. Loosen the 6 screws of the filter
holder (see Fig.10).
2. Carefully release the locking device
from the top.
3. Pull out the filter holder.
4. Clean the filter holder with a suitable
brush or vacuum cleaner.
5. Place the foam filter and the filter
grille into the filter holder again.
Fig. 10 Rear of the appliance
RISK OF ELECTRIC SHOCK!
• Never immerse the mobile air
conditioner or the remote control in
water for cleaning.
• Do not use steam cleaners for
cleaning.
APPLIANCE DAMAGE
RESULTING FROM
INCORRECT OPERATION!
Improper cleaning can result in damage
to the mobile air conditioner.
• Do not use:
→ Aggressive cleaning agents
→ Brushes with metal or nylon
bristles, or
→ Sharp, metallic cleaning aids
such as knives, hard spatulas,
etc.
These can damage the surfaces.