2. Playing the AX100G
Example display
Program mode
When you turn on the power, the AX100G will always enter Pro-
gram mode, and will be set to the program setting that were last
selected when the power was turned off.
Input level switch setting
Set this switch according to the output of your instrument.
H : Suitable for a pickup with a high output level, such as a
humbucking pickup
L : Suitable for a pickup with a low output level, such as a single
coil pickup
Adjusting the volume (master volume)
To adjust the volume, rotate the MASTER VOL. (master volume)
located on the rear panel.
Selecting a program
Press the UP or DOWN switches to increment or decrement the
programs in steps of one. When you do so, the multi-display
will show the name of each program.
Programs are organized into groups of four, and these groups
are called "banks." The current bank is shown by the 10's digit of
the number LED.
User program
Preset program
The AX100G contains a total of 80 programs (sounds): 40 (4 x 10
banks) of preset programs that cannot be overwritten, and 40 (4
x 10 banks) of user programs that you are able to modify (edit).
When a user program is selected, the decimal point (dot) in the
lower right of the number LED will light.
User
program
Preset
program
Dot is lit
Selecting a bank
Although you can use the UP or DOWN switches to select pro-
grams across banks, you can also switch programs by bank.
1. Press and hold the PROG/FX SELECT switch for approxi-
mately one second until the number LED begins to blink.
2. Press either the UP or DOWN switch to increment or decre-
ment the bank.
3. Press the PROG/FX SELECT switch once again to finalize the
bank and make the number LED stop blinking.
Bank Hold (10’s HOLD)
By simultaneously pressing the TAP switch and EXIT switch,
you can prevent programs of other banks from being selected.
At this time, the decimal point (dot) at the lower right of the 10's
place in the number LED will light.
Press the UP or DOWN switches to select programs within the
current bank.
When you once again press the TAP switch and EXIT switch
simultaneously, the Bank Hold (10’S HOLD) function will be can-
celled.
Dot is lit
Checking the effects used by a program
Some programs do not use all of the effects. When you select a
program, the LED beside each effect select switch will light to
indicate the effects that are being used. An effect that is turned
off can be edited (turned on) by pressing its select switch, and
when you press another select switch or the EXIT switch, the
LED will change from blinking to lit.
Bypass, Mute
By pressing the UP and DOWN switches simultaneously, you
can Bypass the AX100G so that no effects will be applied. (The
multi-display will indicate "BYPASS" for two second.)
Alternatively, by pressing the UP and DOWN switches simulta-
neously and holding them for approximately one second, you
can Mute the AX100G completely so that no sound will be out-
put. (The multi-display will indicate "MUTE" for two second.)
To defeat Bypass or Mute, press the UP or DOWN switch.
Auto tuner
When the AX100G is in bypass or mute condition, the tuner will
operate automatically. If you mute the AX100G you will be able
to tune your instrument without producing sound. This is used
for on stage tuning.
1. Tune your guitar so that the desired note
name appears in the number LED. The
decimal point “.” at the lower right of the
number LED will light to indicate a sharp
.
2. The seven-point pedal indicator will show the difference be-
tween the pitch you play and the note name. Tune your in-
strument so that only the center LED is lit.
Tuning discrepancy shown by the pedal indicator
and the multi-display
Correct
tuning
Pitch is
flat
Pitch is
sharp
Changing the calibration setting
As necessary, you can adjust the calibration (the frequency of the
standard A pitch) in the range of 438—445 Hz. (440 Hz is “stan-
dard”)
When the tuner is operating, you can rotate value knob 1 to ad-
just the calibration. The calibration setting is shown in the multi-
display.
When the power is turned off, the calibration setting you modify
will be lost, and will automatically return to 440 Hz the next
time the power is turned on.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Korg AX100G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info