Setting the word clock source on an ADAT system
ADATs have three settings for word clock source: “Digital,” “Internal,” and
“External.”
Digital means that they sync to an external clock through their optical or 9-
pin inputs, if they are connected to another ADAT optical device (such as
the 1212 I/O); if there are no other devices connected, then they use their
internal clock.
Internal means that they use their internal clock, regardless of any signal at
the optical input.
External will only appear if the ADAT is connected to a BRC, or another
ADAT sync master (such as the Mark Of The Unicorn MIDI Timepiece AV).
In a multi-device system without the Alesis BRC, the first device (the unit
that displays “Id 1” at startup) will have been designated the word clock
master at startup, and this is the only one you need to change. The rest of
the devices will automatically be set to slave to the master through their
digital inputs.
When using the Alesis BRC, you do not need to make any settings on the
ADATs themselves (they’ll automatically be set to External); instead, the
BRC controls the word clock of the connected ADATs. See below for
instructions on working with the BRC.
ADAT XT, Fostex CX-8, Panasonic MDA-1 (without BRC)
On the ADAT XT, Fostex CX-8, and Panasonic MDA-1, both the word clock
source and the sample rate are set using the Clock Source button on the
front panel. The current Clock Source setting is shown in the lower right-
hand side of the fluorescent display. Pressing the button repeatedly toggles
through the four choices: INT 48kHz, INT 44.1kHz, DIG 48kHz, and DIG
44.1kHz. “INT” is Internal, and “DIG” is Digital.
If the ADAT is providing the master clock source, the sample rate (48kHz
or 44.1kHz) will control the entire system, including the 1212 I/O. If the
tape is not formatted for the current sample rate, the sample rate may flash
in the display, and the front-panel clock may not be correct, but otherwise
everything will be fine; please see your ADAT manual for details.
If DIG is selected, the on-screen “DIG” indicator will flash if there is a
problem with the signal at the ADAT’s optical input (such as no cable
connected, or invalid word clock).
Original ADAT (without BRC)
On the original ADAT, hold the “SET LOCATE” button, and then press
“DIGITAL IN.” This toggles the ADAT between “int” (Internal) and “dig”
(Digital). This is a little tricky, since you cannot see the setting without
changing it. Press the buttons until you see the desired setting.
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Korg SoundLink DRS 1212 I-O wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Korg SoundLink DRS 1212 I-O

Korg SoundLink DRS 1212 I-O Bedienungsanleitung - Deutsch - 67 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info