813960
15
Zoom out
Zoom in
Vorherige Seite
1/136
Nächste Seite
15
EN
ber requires about 8 m3 of air. In the room in which the replace insert is to be installed that draws air
from the room, there must be no exhaust devices or other appliances equipped with a hearth. In rooms
with mechanical ventilation or very tight window frames, an individual air supply to the combustion
chamber of the insert should be used. It is best to use a fresh air intake from the outside for this pur-
pose. In the case of cast iron inserts with an optional intake, the intake system should additionally be
equipped with a damper so that the room does not lose temperature when the replace is not in use.
The air intake supplying combustion air should be selected so that it cannot become clogged. Inserts
with sealed combustion chamber SERIES NB, MB, NADIA, VN, LUCY, ZIBI realize air intake through the
intake nozzle. Eective combustion is guaranteed only by connecting the air intake from the outside.
Lack of such connection may result in inecient combustion, dirtying of windows.
The replace must not be exposed to moisture. If the chimney insert is installed at the stage of con-
struction and nishing works, care should be taken to protect the replace from moisture associated
with the conduct of so-called wet works such as plaster, plasterboard. In this case, you should also pay
special attention to the fuel used, so that construction waste and other materials than recommended
are not burned in the replace, as this can result in overheating of the insert and numerous damages.
Construction of the replace insert housing
The cladding should be designed so that the replace insert is not permanently attached to it, with
the ability to be installed and removed without damaging it. The cladding should allow easy access
for inspection of the chimney connector, operation of the shaft or chimney draft regulator (if these
are installed). Non-ammable and insulating materials should be used for the construction, such as
aluminum-coated mineral wool, ceramic bers, glass ber-reinforced heat-resistant plates, aluminum
coatings. The distance of insulation from the walls of the replace insert should be 8 - 12 cm. The di-
stance between the frame of the replace and the casing must not be less than 5 mm (the expansion
joint does not require insulation). The cladding should provide access to the air needed for combu-
stion, as well as ventilation of the replace, through the use of appropriate grilles selected according to
the power of the device. At the bottom of the replace stove enclosure should be installed inlet grille
through which air is supplied to the housing (40-60 cm2 / 1 kW). To ensure proper discharge of hot air
from the hood, an air outlet grille must be installed in the hood. The minimum active area of the grilles
is selected depending on the power of the insert: from 50 to 70 cm2 per 1 kW.
A very high temperature is reached inside the housing, so a decompression shelf should be installed
in the housing at a distance of about 40 cm from the ceiling. It prevents heating of the ceiling in the
room, heat loss, and forces the installation of outlet grilles under it at the appropriate height that emit
heat from the chamber above the replace. Decompression grilles are installed on two sides of the
enclosure alternately, for example, alternately higher and lower above the decompression half. The
size of the grilles and their active area is not important.
Note
Due to the high temperature in the insert housing, the grilles in the hood as well as the crown of the
air distribution system in the house must be metal. In the replace hood, we only install grilles without
louvers.
OPERATION OF THE FIREPLACE INSERT
When cold, the replace insert should have all the dampers closed so that the room in which it is
installed does not lose temperature when the replace is not in use. Closed dampers will also prevent
the possibility of condensation on the lower parts of the insert, especially the sill, The appearance of
condensation can result in corrosion of steel components. Do not use an uncovered replace insert
except for test kindling. BASIA and MILA replace inserts must be equipped with a manual or auto-
matic ue gas damper mounted on their inlet. To purchase a compatible damper, contact the sales
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kratki VNP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info